Prime Hydraulic Pump:

Hydraulic Oil Installation 2 WD & 4 WD

1.

The Hydraulic Pump

MUST be Primed.

The hy-

draulic pump is primed by putting
oil directly in to the pump. Looking
at the pump, out near the end of the
pump there is a Allen plug (See
Figure 5). Remove this plug and
install only approved hydraulic oil (
See Step 1 through 3 of hydraulic
tank filling). Fill the cavity completely
full up to plug threads. IMPOR-
TANT! This must be done before
the unit is ever started. Make cer-
tain that the O-Ring Seal is on plug
and reinstall it after cavity is full of
oil, now the pump is primed. The
Unit still will not operate until the
next step of setting the electronics
to operate the system.

Remove This allen head

plug to Prime Pump

Figure 5

ATTENTION

20°F

10°F

30°F

40°F

60°F

70°F

90°F 110°F

AW ISO VG 32

AW ISO VG 46

AW ISO VG 68

AW ISO VG 100

The correct hydraulic fluid is dependent upon ambient
temperature. Refer to chart when selecting proper grade