Appendix b - glossary – Fluid Components International FR73B Complete Manual User Manual

Page 13

Advertising
background image

FR78B Flow Switch/Monitor

FLUID COMPONENTS INTERNATIONAL LLC

This page is subject to proprietary rights statement on last page

13

Doc. No. 06EN003281 Rev. A

Appendix B - Glossary

ABBREVIATIONS

Delta R (DR)

Differential Resistance

Delta T (DT)

Differential Temperature

DMM

Digital Multimeter

FCI

Fluid Components Intl

HTR

Heater

LED

Light Emitting Diode

RA

Repair Authorization

RTD

Resistance Temperature Detector

DEFINITIONS

Active RTD

The flow element part that senses the fluid flow rate.

Balance

A number that is used to balance or match the

active and reference RTDs when the heater is off.

Control Circuit

The portion of the flow switch that conditions, converts, and scales

the flow element signal.

Differential resistance

Delta -R (DR)

The flow element signal.

Differential temperature

Delta -T (DT)

The difference in temperature between the active and

reference RTDs.

Flow element

The portion of the flow switch that contains the thermowells, RTDs,

and produces a signal with a defined relationship to the flow rate.

Heater (HTR)

The flow element part that heats the active RTD.

Reference RTD

The flow element part that senses the fluid temperature.

Remote enclosure

The enclosure that contains the control circuit, and is

connected to the flow element by an electrical cable.

Resistance Temperature

Detector (RTD)

A sensor whose resistance changes proportionally to detector
temperature changes.

Advertising