A series, A series technical details, Resistance readings (ohms) pump weight – HOMA A Series User Manual

Page 16: Approx. (lbs.)

Advertising
background image

A Series

Installation, Operation & Maintenance Manual

A Series Technical Details

The following is offered as a general guide to values and capacities commonly used.

Resistance Readings (ohms)

Pump Weight

230V 230V 460V

Approx. (Lbs.)

HP / RPM

1 Phase

3 Phase *

3 Phase *

U1 - U2 / U1 - Z2

U-V-W

U-V-W

2.5HP-1750 D 2.2 5.0

1.5 5.0

230 #

2.8HP-1160 T N/A 2.7 5.0

230 #

2.9HP-1750 N 2.2 5.0 3.1 11.0

230 #

2.9HP-1750 T

1.6 4.4 3.1 11.0

230 #

3.5HP-1750 D N/A 1.9 5.5

230 #

3.8HP-1160 T N/A 1.5 2.5

240 #

4.3HP-1750 N 1.5 3.0 1.5 4.2

240 #

4.3HP-1750 T

1.5 4.2

240 #

5.1HP-1750 T

1.1 2.6

N/A

N/A

250 #

5.5HP-1750 N 0.9 1.9 1.3 3.7

250 #

5.5HP-1750 T

N/A 1.3 3.7

250 #

6.2HP-1160 T N/A 1.3 3.7

250 #

6.7HP-1750 T

0.7 1.9

N/A

N/A

260 #

7.5HP-1750 N 0.8 1.5 0.9 2.6

260 #

7.5HP-1750 T

N/A

1.2

3.0

260 #

8.3HP-1160 T N/A 0.9 2.6

260 #

9.7HP-1750 T 0.5

1.4

N/A N/A

260 #

9.8HP-1160 P N/A 0.7 2.2

290 #

10HP-1750 N 0.3 0.9 0.6 1.9

290 #

10HP-1750 T

N/A

0.6

1.9

290 #

11.4HP-1750 T

0.4 0.8

N/A

N/A

290 #

13HP-1750 P N/A 0.5 1.8

350 #

15.3HP-1160 P N/A 0.5 1.1

350 #

20HP-1750 P N/A 0.5 1.1

400 #

21.5HP-1160 P N/A 0.5 1.1

400 #

29HP-1750 P N/A 0.4 0.7

500 #

*Values should be as indicated between any 2 power leads.
Note: Resistance values include 30’cable, and should be within +/- 10% of above value.

Above 30 HP, resistance values between 230 and 460 volt machines vary by less than 0.1 ohm. Consult
factory with specific requirements.

Impeller Bolt Torque: 10MM- 26FT#, 12MM-45FT#, 16MM-108FT#, 20MM- 210FT#

Impeller to Bottom Plate Clearance: (ASC) .020” minimum clearance.

Pump Rotation Right hand (CW) looking down from top of motor, CCW looking at bottom of pump.

Seal Probes: N motor pumps use a 12mm seal probe P motor pumps use 20mm seal probe.
Single wire probes are for non classified areas, and 2 wire probes are for Hazardous areas.