Installation, Operation & Maintenance Manual

Wire Markings of Power & Control Cables


Wire Marker

Wire Connection

Normal Value


Power Cable (s)

L3

Power Supply

See Enclosed Wiring Diagram

L2

Power Supply

See Enclosed Wiring Diagram

L1

Power Supply

See Enclosed Wiring Diagram

Yellow/Green - Ground


Control Cable (s)

T1

Thermal Switch

N.C. .4 ohm

T2 or T3

Thermal Switch

N.C. .4 ohm

K1

Thermistor (optional)

N.C. 268 ohm

K2

Thermistor (optional)

N.C. 268 ohm

P1

Lower Bearing Temp. PT100

N.C. 108 ohm

P2

Lower Bearing Temp. PT100

N.C. 108 ohm

P3

Lower Bearing Temp. PT100

N.C. 108 ohm

P4

Lower Bearing Temp. PT100

N.C. 108 ohm

S1*

Oil Chamber Seal Probe

1 or 2 wire probe

N.O.

S2

Oil Chamber Seal Probe

2 wire probe

N.O.

S3

Connection Chamber Seal Probe

2 wire probe

N.O.

S4

Connection Chamber Seal Probe

2 wire probe

N.O.

S5*

Stator Housing Leak Detector

1 wire probe

N.O.

S7

Stator Housing Leak Detector

Level Switch

N.C. .7 ohm

S8

Stator Housing Leak Detector

Level Switch

N.C. .7 ohm

Yellow/Green –Ground - *Must be used to complete 1 wire probe circuits!


Note: Pump may have single or multiple power or control cables. Verify all
wire connections are correct before applying power to any circuit. Improper
power supply can permanently damage certain control devices.


All control or monitoring devices must be connected to a suitable power
supply and sensing device. Homa can provide an optional Go Switch for
any of these control or monitoring devices. Consult your local Homa
distributor