A Series Technical Details

Seal Chamber Oil: White Mineral Oil (Chevron Lubricating Oil FM 32, 46, 68)

Seal Oil Volume

ALL N FRAME MOTORS 2.5L
ALL T FRAME MOTORS

2.5L

ALL P FRAME MOTORS

3.7L

CURRENT D MOTORS________0.9L
F, G & H FRAME SEAL OIL VOLUTE VARY BY HP, PLEASE CONSULT FACTORY WITH SPECIFIC
PUMP MODEL.

Seal Oil Level
With pump lying on its side and oil port at 12:00, measure from the top of housing with gasket in place, to
the oil level.

A Series T, N & P motors:

1 1/2” from top of housing to oil level


Minimum Distance between 2 pumps

3” Discharge 4” Discharge 6” Discharge

8” & Larger

AK Min N/A Min 10”

Min 13”

Please consult

AV Min 8” Min 10”

Min 13”

factory for lay-

AMX Min 8” Min 10”

Min 13”

out information