background image

Publication

88FN2040A

Please Contact Technical Support At 203-736-8890 With Any Additional Questions

Please Be Prepared To Provide Pump Serial Number During Call

Page

2 of 4


4. With motor cap removed, use a capscrew

that was removed from motor cap to
support motor cap as shown. Stator
windings and cable leads must be visible
and easy to reach. Your unit should now
look like this. Gently remove all wires
from around the stator windings. Take
care not to damage the winding
insulation. Do not use sharp tools!!


5. Separate the wire bundles as indicated,

and record the wire numbers in each
bundle.


If pump is wired for 208/230V, it will have 4
wire bundles. If pump is wired for 460V, it will
have 6 wire bundles.

Bundle 1 ___

___

___


Bundle 2 ___

___

___


Bundle 3 ___

___

___


Bundle 4 ___

___

___


Bundle 5 ___

___

___


Bundle 6 ___

___

___


Note: If the power cable is 4 lead, the wires
are color coded. If the power cable is 7 lead,
each individual wire will have a number on
cable sheath.

6. To convert from 230V to 460V operation,

you will need to separate the wire
bundles, one at a time, and reconnect as
indicated below.