Please Contact Technical Support At 203-736-8890 With Any Additional Questions

Please Be Prepared To Provide Pump Serial Number During Call

Page

3 of 4

7. To perform the reconnection, locate the

wire bundle with wires 1, 7, and a power
lead. Cut wire number 7 from the bundle,
freeing individual wires. Strip wire
sheathing back ¼ in preparation for
reconnection.


8. Repeat procedure for wire bundle 2, 8,

and power



9. Repeat procedure for wire bundle 3, 9,

and power. Leave wire number 9 loose
for now.


Now you should have three new bundles
2 and power
3 and power
1 and power
along with 3 separate wires (#7,#8,#9), and
one bundle of 3 wires (#4,#5,#6).






10. Now, you will need to separate the wire

bundle numbers 4, 5, 6, and pair each
wire with the loose wires numbers 7, 8, 9
as indicated. Using the last three wire
connectors:

Join wire #4 to wire #7
Join wire #5 to wire #8
Join wire #6 to wire #9



11. At this point, you should have 6 separate

wire bundles, each with 2 wires. Wires
should be paired as follows: 4 to 7, 5 to 8,
6 to 9, number 1 to power, number 2 to
power and number 3 to power. See photo


Before proceeding, you should check the
resistance between all three cable leads
is the same. Resistance value is different
for the various size motors, so please
consult wiring handbook for specific
resistance values, if required.