HOMA A Series Voltage Change User Manual

Page 4

Advertising
background image

Publication

88FN2040A

Please Contact Technical Support At 203-736-8890 With Any Additional Questions

Please Be Prepared To Provide Pump Serial Number During Call

Page

4 of 4

12. Starting with bundles 4-7, 5-8, 6-9, gently

tuck these 3 wire bundles behind the
windings on one side of stator. Then slide
insulation wrap back over wires then tuck
the remaining 3 bundles behind the
windings on the other side. Take care that
all wires are tucked in between stator
winding and housing. Also check that
white phase paper is in proper position,
and not extending above the stator
housing.


The pump is now ready for reassembly





13. Verify that the large o ring is still in its

proper position on the pump housing.
Gently place motor cap back onto pump.


14. With motor cap back in position, then

align bolt holes and replace capscrews.
Tighten capscrews to 12 ft/lbs.



15. Pump should now be ready for installation

and operation at 460V. Be sure to record
that voltage has been changed in pump
service manual.

Advertising