Tsunami applicator specifications, Chemical dispensing specifications – Hydra-Flex Aqua-Lab + Tsunami Operating Manual User Manual

Page 2

Advertising
background image

© Hydra-Flex Inc 2011

- 2 -

Chemical Dispensing Specifications

1.

Operating water pressure: 200 psi (Factory set)

2.

Maximum water source temperature 140° F

3.

Operating ambient temperature: 40-120° F

4.

Electrical supply

a. 120 / 208 Single Phase
b. 1.5 hp pump 20 amps @ 120 volts or 10 amps @ 208

volts

5.

Operate valves with 24VAC, 24VDC, 120VAC

a. < .5 amp

6.

Water supply

a. 3/4

” ID flooded inlet required

b. Inlet pressure: 2-60 psi

7. Air supply

a. Pneumatics inlet pressure: 60 - 100 psi
b.

3/8” feed per system

c. 20 CFM @ 100 psi supply
d. 3

x 3/8” poly lines to applicator

8. Chemical Solution lines

a. 3x

½” poly lines to applicator

9.

Space requirements:

a. AQUA-LAB Systems

i. Valve panel

– 1.5’ wide x 2’ tall

ii. Pump

– 1’ wide x 4’ tall

b. Pump assemblies

– pumps need to be within 6’ of the

system to allow connection with the connection hose
included (longer connections can be run with customer
supplied hose)

c. Electrical enclosures

i. Motor starter

– 12” wide x 6” tall

Tsunami Applicator Specifications

1. Operating water pressure: 100 psi max

2.

Pneumatics inlet pressure: 0-60 psi

3.

Maximum water source temperature 140° F

4.

Operating ambient temperature: 40-120° F

5.

Water supply

a. 4

– 10 GPM

b. Inlet pressure: 10-65 psi

6. Air supply

a.

3x 3/8” feed per system

b. ~20 CFM

7. Solution lines

a. 3x

½” poly lines to applicator

8.

Mounting requirements

a. This Applicator requires an arch to mount to
b. Must be level
c. Recommend roughly centering on car or slightly favoring the

driver’s side