Optimizing the system, Injectors vs. metering tips – Hydra-Flex Aqua-Lab + Tsunami Operating Manual User Manual

Page 6

Advertising
background image

© Hydra-Flex Inc 2011

- 6 -

Optimizing the System

Consistently achieve the desired cleaning and presentation/performance

using the least amount of chemical and water


Injectors vs. Metering Tips

The key to optimizing the system is through trial and error.

Don’t be afraid to try these steps to achieve your ideal performance.

What do injectors do?

o Increases or decreases the amount of water

in the solution

What do metering tips do?

o Increases or decreases the amount of

chemical in the solution


Application Optimization (repeat for each
application)

View Performance at Arch with Decision Maker

Application too wet

o Increase air
o Reduce injector size (decreases water)
o Increase metering tip (increases chemical)

Application too dry

o Decrease air
o Increase injector size (increases water)
o Decrease metering tip (decreases chemical)

Too much chemical used

o Decrease metering tip
o Decrease metering tip and injector size (to maintain desired ratio)

No chemical

o Check vacuum of injector (see instructions on page 9)
o Check foot valve
o Check metering tip

Advertising