R M - 7 0 2 T W O - C H A N N E L R E M O T E S T A T I O N

2 - 2

Figure 2-2: RM-702 PCB Layout

To connect or isolate RM-702 channels:

1. Please observe anti-static procedures. The circuit cards can be damaged

by static electricity. Please ground yourself and tools before touching any

circuit cards.

2. Remove the cover of the RM-702.
3. On the main circuit board, locate the JP4 three-pin jumper.

The jumper is located on the rightmost upper portion of the circuit card,
when viewed from the front of the unit. The label “J4” appears behind the
jumper. A jumper plug is placed over pins 2 and 3.

4. Do one of the following:

• To connect the two channels, place the jumper plug over pins 1 and 2.

Figure 2-3: Jumper Set to Connect Channels

• To isolate the two channels, place the jumper plug over pins 2 and 3.

Figure 2-4: Jumper Set to Isolate Channels

JP4

JP2

JP3

JP6

JP5

JP4

1

2

3

JP4

1

2

3