Unlinking morninglinc from an insteon controller, Advanced features, Restoring power to morninglinc – INSTEON MorningLinc (2458A1) Manual User Manual

Page 6

Advertising
background image

MorningLinc Owner’s Manual

Page 6 of 9 2458A1 - Rev: 1/21/2014 8:44 AM


The MorningLinc Status LED will flash once and then turn on if the door is locked or turn off if the
door is unlocked.

5) Confirm that linking was successful by locking/unlocking the door and tapping the Off button you just

linked to on the controller.

MorningLinc will respond appropriately.

Unlinking MorningLinc from an INSTEON Controller

If you are going to discontinue using MorningLinc, it is very important that you unlink it from any linked
controllers. Otherwise, the controllers will retry any commands repetitively, thus slowing down the system.

NOTE: If you unlink MorningLinc from a single button of an On/Off button pair, any linked commands for
the controller will be erased, even if the commands were linked to separate buttons. After unlinking, you
will have to relink the commands you wish to continue using on the controller.

The following will work for the most common INSTEON devices:

1) Set the controller to unlinking mode. (For most controllers, press and hold an On or Scene button for

10 seconds twice or the Set button for 3 seconds twice.)

You will have 4 minutes to complete the next step before unlinking mode automatically times out.

2) Press and hold MorningLinc’s Set button for 3 seconds.

The MorningLinc Status LED will flash once and then turn on solid if the door is locked or turn off
if the door is unlocked.

3) Confirm that unlinking was successful by locking/unlocking the door and pressing the button you just

unlinked from on the controller.

MorningLinc will no longer respond.

4) If there are any commands you would like to continue using with the controller, relink them with the

prior settings. See Linking an INSTEON Controller to MorningLinc.

ADVANCED FEATURES

Restoring Power to MorningLinc

MorningLinc stores all of its settings, such as links to other INSTEON devices, in its non-volatile memory.
Because settings are saved in this internal memory, they will not be lost in the event of a power failure.

Resetting MorningLinc to its Factory Default Settings

The factory reset procedure can be used to clear the MorningLinc memory of all INSTEON links.

1) If you are using a controller to control MorningLinc, be sure to unlink it from the controller. See

Unlinking MorningLinc from an INSTEON Controller.

2) Unplug MorningLinc for about 10 seconds.

3) While holding down MorningLinc’s Set button, plug it back in, making sure not to let go of the Set

button.

The MorningLinc Status LED will turn on solid.

4) Continue to hold down the Set button for 3 seconds and then release.

After a few seconds, the MorningLinc Status LED will flash once and then turn on solid.

NOTE: If you wish to use MorningLinc to lock and unlock your door again, you will need to reinstall
MorningLinc. See Installing MorningLinc and start from step 3.

Advertising