For proper performance – King Technology Sparco System User Manual

Page 11

Advertising
background image

B. With In-floor Cleaners

A. With High GPMS
Install T-fittings exactly as shown.

C. Pool and Spillover Spa Combination

TO POOL

TO SP

A

3-WAY VALVE

SPARCO
CYCLER

CHECK VALVE

PUMP

TO

POOL

SPARCO
CYCLER

CHECK
VALVE

For Proper Performance

§

§

§

§

§

§

§

§

§

§

§

§

§

§

§

§

§

§

SPARCO
CYCLER

PUMP

3-WAY VALVE

11

SUCTION
FROM
POOL/SPA

SUCTION
FROM
POOL/SPA

IN-FLOOR
VALVE

POOL WATER LEVEL

1) Run pump for at least 6 hours per
day at high speed (at least 40 gpm).

If the pump will run on low speed 24 hours
per day or less than 6 hours per day on
high speed, you must bleed the air while
the pump is on by unscrewing the cap
knob until water appears. Then screw the
knob back on. Repeat this process each
time the cap is removed for any reason.

2) Install system with a minimum 4 psi
back pressure.

Lower back pressures could result in under
chlorination. Adjust eye ball fittings in the
return jets to a smaller size to increase
back pressure. Contact King Technology
at 800-222-0169 for a cap tapped for a
pressure gauge to determine back
pressure at pool start-up.

3) Special installation:

A. Water flow is higher than 80 gpm.

B. In-floor cleaner is included with pool.

C. Pool and spa combination with common
equipment.

NOTE: Over chlorination or damage to the
Sparco Cyclers or other equipment could
result if these special installations are not
used in these situations.

AUTOMATIC

WATER

TREATMENT

SYSTEM

Advertising