In ground, in-line installation, Water – King Technology Sparco System User Manual

Page 8

Advertising
background image

AUTOMATIC

WATER

TREATMENT

SYSTEM

Brush sealant on the
threads of both male
adapters.

DO NOT USE TEFLON
TAPE as the threads
on these units
are not suitable
for this use and
leaking or fitting
failure could result.

In ground, In-Line Installation

PVC

CEMENT

PIPE

THREAD

PVC

CEMENT

400 SERIES

Water

CYCLER

Metere

d Pool Purifier

Water

CYCLER

Metere

d Pool Purifier

PIPE

THREAD

PIPE

THREAD

Water

CYCLER

Metere

d Pool Purifier

Water

CYCLER

Metere

d Pool Purifier

Water

CYCLER

Metere

d Pool Purifier

Corrosion Resistant
Check Valve

Can be installed with the
water flow in either direction
due to its bi-flow control dial.

TOOLS NEEDED:

Pipe Wrench

Following pipe thread sealant
directions, brush sealant on
to Sparco Cycler threads in
both ports.

Screw a male adapter
into each port of Sparco
Cycler and hand tighten.

Completely tighten
turning 1 to 2
revolutions
with wrench.
DO NOT
OVER TIGHTEN.

Following PVC cement
directions brush PVC
cement on ends of pipe and
the inside of bushings.

Insert PVC pipe into
bushings. Hold in place
5 to 10 seconds to bond.

Installing a corrosion
resistant check valve is
recommended.

Hacksaw

Do NOT install
an in-line
Sparco Cycler
off-line.

Install after all equipment and as far as possible from heater.

Do NOT
install in
copper pipe
as chemical
corrosion
occurs.

Leave 12" to
15" above and
around Sparco
Cycler to allow
room for easy
chamber
replacement.

12" to 15"

12" to 15"

MATERIALS NEEDED:

PVC
Cement

Pipe Thread
Sealant

Two 2" Threaded

X

2" or 1 1/2" Slip

PVC Male Adapters
(not included)

#10

X

1 1/4" Phillips Pan

Head Screws with
Washers

RECOMMENDED:

Use Phillips pan head
screws through the
mounting holes at the
Sparco Cycler base to
secure the Sparco Cycler
into a treated wood base.

1.

2.

3.

4.

5.

6.

8

ATTENTION BUILDER:
Call 800-222-0169 for an
In Ground test cap to use at
start-up to ensure proper back
pressure.