Termination switch setting, Communication protocol setup – CNB SKB-21Z12F User Manual

Page 6

Advertising
background image

◎ Termination switch(Pin 6~7) is used in cases listed below.

Termination Switch Setting

◎ Select the appropriate Protocol with DIP switch combination. (Pin 1~3)

Communication Protocol Setup

Long-distance communication between the controller and the camera (1-to-1

connection)

- When the connecting distance between the two units is especially long,

communication errors may occur due to the impedance of transmission cable. In this

Termination Switch is used in case listed below.

NO

PROTOCOL

BAUDRATE

#1

#2

#3

0

SONY

9600bps

OFF

OFF

OFF

1

SONY

38400bps

ON

OFF

OFF

2

PELCO-D

2400bps

OFF

ON

OFF

communication errors may occur due to the impedance of transmission cable. In this

case, set the termination switch of both units to ON.

Controlling multiple cameras (Multiple connection)

- The camera may not operate correctly if multiple cameras are connected and

controlled. In this case, set the termination switch of the controller and the last

connected camera to ON and the switch of other cameras is OFF.

3

PELCO-D

9600bps

ON

ON

OFF

4

PELCO-D

38400bps

OFF

OFF

ON

5

PELCO-P

4800bps

ON

OFF

ON

6

PELCO-P

9600bps

OFF

ON

ON

Others

Reserved

◎ If you want to control using DVR or P/T controller, their protocol must be identical to

camera. Otherwise, you can not control the camera.

◎ If you changed camera protocol by changing DIP S/W, the change will be effective

after you reboot the camera.

Others

Reserved

RS485

RS485

RS422

10

11

#1

#2

#n

Advertising
This manual is related to the following products: