See section “6.1. alarm-in and alarm-out – CNB IG1810PF User Manual

Page 8

Advertising
background image

XNET Network Box Camera User’s Guide

y 1

aseT

: 100Mbps Ethernet connector (RJ-45) with proprietary PoE.

00B

S-2

- Status LED: Green color indicates that the camera is in normal operation mode, while red

color indicates that the camera is in abnormal condition.

When connecting a power source to the XNET, the status LED will be lit red for a
second and then it will change to green.

- Link LED: Continuous yellow light means that network cable is plugged in. It will flicker

when there is traffic.

y R

32C & Video-out: 3 Pins from the bottom of the connector are assigned for RS-

232

port, while the remaining 2 pins are used for checking composite video output from the
camera. Please note that the bottom most pin is numbered as 1.

Pin

Description

Misc.

1

TxD of RS-232C

2

RxD of RS-232C

3

Ground of RS-232C

For debugging & factory

use only.

4

Video out from the camera

For use in installation.

5

Ground for Video out.

For use in installation

5

1

y 1

C:

Power input of XNET/XNET-Wireless.

Do not apply power through this power input when power is applied through LAN cable using
proprietary PoE.

2VD

y RS-485 and ALARM IN/OUT: Used for connecting P/T device, sensor, and alarm devices to

XNET/XNET-Wireless. Pin assignments are as follows

Pin

Description

Misc.

1 RS-485

(-)

2 RS-485

(+)

3

Alarm In (-)

4

Alarm In (+)

NC/NO selectable in admin mode.

5 Alarm

Out

6 Alarm

Out

See section “6.1. ALARM-IN
and ALARM-OUT

6

1

- RS-485

:

Used for connecting Pan/Tilt and Zoom devices having RS-485 interface standard.

- Alarm In:

Connect external alarm sensors such as the

infrared sensors, heat sensor,

magnetic sensors, etc. NC/NO selectable in the admin page.

-

Alarm Out:

It is used for connecting external alarm generators such as sirens, flashing light,

etc. When activated, relay output configures a closed circuit.

Please refer to Section 6.1 for more detailed description on the Alarm In/Out connections.