CognitiveTPG A799 User Manual

Page 103

Advertising
background image

Chapter 4: Programming Commands

103

Revision D 12/09

A799-PG00001D

Set GS1 DataBar (formerly RSS) parameters

Setting of parameters for GS! DataBar

ASCII

GS q a b c d e fL fH

Hexadecimal 1D 71 a b c d e fL fH

Decimal

29 113 a b c d e fL fH

a

byte

pixels per minimum unit, default 3, minimum 2, maximum 6 (value a applies

to parameters b, c, d)

b

byte

X undercut, default 0, can be set 0 to a-1

c

byte

Y undercut, default 0, can be set 0 to a-1

d

byte

separator height, default a, can be set a to a*2

e

byte

segment width, used only by GS1 DataBar Expanded, default 22, must be

even number

2 to 22

f

word

line height, used only by UCC128, default 25, can be set 1 to 500

Note: For GS1 DataBar commands, consult ISO/IEC 24721. For further information, visit www.gs1.org.

Select PDF 417 parameters

ASCII

GS p a b c d e f

Hexadecimal 1D 70 a b c d e f

Decimal

29 112 a b c d e f

Value and Ranges:

Value:

Ranges:

Description:

a, b =

The ratio of bar height to symbol length.

a = height

limit 1 to 10

b = width

limit 1 to 100

c =

rows

limit 3 to 90

Number of rows in the matrix of code words.

d =

columns

limit 7 to 30

Number of columns in the matrix of code words.

e =

x dimension

limit 1 to 7

Width of a single module in dots.

f =

y dimension

limit 2 to 25

Height of the code word in dots.

Defaults:

a = 1

b = 2

c = 58

d = 7

e = 3

f = 10

PDF 417 is a multi-row, continuous, variable length symbology which has high data capacity. Each symbol has between 3
and 90 rows, with each row containing a start pattern, a left row indicator, 1 to 30 data characters, a right row indicator and
a stop pattern. The number and length of the rows are selectable, which allows the aspect ratio to be adjusted to particular
labeling applications. There are no separator bars between rows.
Each character has four bars and four spaces within 17 modules, and is assigned a value between 0 and 928. For this
symbology, it is common to refer to these character values as “code words.”
There are three mutually exclusive sets of symbol patterns, or clusters, each having 929 distinct patterns. Because different
clusters are used for adjacent rows, it is possible for the decoder to tell if the scanning path is crossing row boundaries
without the use of separator bars.

Advertising