communications failed or that the write to flash failed. The alternatives seem to be to retry the block or halt loading and
assume a hardware failure.
Related information

Available only in download mode.

Reset firmware

ASCII

GS (SPACE)

Hexadecimal 1D FF

Decimal

29 255

Ends the load process and reboots the printer. Before executing this command, the printer should have firmware loaded and
external switches set to the runtime settings. Application software for downloading should prompt the user to set the external
switches and confirm before sending this command. If the downloading was started from a diagnostic, the reboot will cause
the printer to re-enter download state unless the external switches are changed.

Ethernet setup commands

The following commands are designed to set the required printer internal parameters for Ethernet operation. The
commands can be used only in the Flash download (boot) mode. See Chapter 3 for default setup.

Restore default settings

ASCII

US BS NUL

Hexadecimal 1F 08 00

Decimal

31 8 0

Restores the Ethernet settings to the preset values.

Default settings are:
IP address:

192.0.0.192

(in use after boot timeout of two minutes)

Net mask:

0.0.0.0

(default mask of selected IP is used)

Gateway:

none

Raw TCPIP port 9001:

active

Telnet Daemon:

enabled

LP Daemon:

disabled

Bootp:

disabled

DHCP:

enabled

Inactivity timeout:

enabled

Keep alive pings:

disabled

Setting IP address

ASCII

US BS SOH n1 n2 n3 n4

Hexadecimal 1F 08 01 n1 n2 n3 n4

Decimal

31 8 1

n1 n2 n3 n4

Default:

192.0.0.192

Sets the IP address value specified by the values of n1 to n4.

Setting Net Mask

ASCII

US BS STX n1 n2 n3 n4

Hexadecimal 1F 08 02 n1 n2 n3 n4

Decimal

31 8 2

n1 n2 n3 n4

Default:

0.0.0.0

Sets the Net Mask value specified by the values n1 to n4.