Connectors – CTI Products CIB Comparator Interface User Manual

Page 17

Advertising
background image

CIB Hardware Reference

Connectors

CTI Products, Inc.

68-10854-135

11

5. Connectors

The NETWORK IN/OUT ports on the front of the CIB are used to connect the
CIB with other MCN modules. These ports carry both the network data signals as
well as DC power for power distribution with other modules. Table 7 gives the
pinout for these connectors. Figure 5 shows the location of pin 1 for each port.

CA-80068-100

DC IN

IN

OUT

NETWORK

PRODUCTS, INC.

PIN 1

Figure 5 - Network IN/OUT Ports

Pin

Function

1

DATA +

2

DATA -

3

+ POWER

4

No Connect

5

No Connect

6

- POWER

7

- POWER

8

+ POWER

Table 7 - Network Connector Pinout

The DC IN port provides the primary power connection to the module. Power is
distributed through the NETWORK OUT connector to provide power to the
NETWORK IN connector of the MCN unit it is connected to. Each power
supply can power up to four units total. See reference 1 for complete details of
connections to the network and DC IN connectors.

Connector J1 provides the discrete I/O for the receiver signals. Table 9 gives the
pinout for this connector. Table 8 describes the functions of the I/O signals.

Advertising