CIB Hardware Reference
Connectors
CTI Products, Inc.
68-10854-135
12
Signal
Direction
Description
VOTE
Input/Output Output activated to force vote a receiver.
Comparator grounds input to indicate a voted receiver.
RX
Input
Ground to indicate that a signal is being received.
DIS
Input/Output Output activated to disable a receiver.
Ground input to indicate a disabled receiver.
FAIL
Input
Ground input to indicate a failed receiver.
MON
Output
Activated to force vote a receiver in the TAC and Ericsson /
G.E. comparators. Unused for all other comparators.
Table 8 - I/O Signal Descriptions