Possible cause, Corrective action, Manage devices window – CTI Products TurboVUi Dispatch Client Software User Manual

Page 43: Times reported by ip gateways are not synchronized, Ptt devices, Anage, Evices, Indow

Advertising
background image

TurboVUi Dispatch

Software Installation and Configuration Guide

43

Possible Cause

Audio playback device such as speakers or headset is not configured and listed in the

Audio Presets

of the

Options

menu.

Corrective Action

From the Edit mode, configure

Audio Presets

for speakers or headset.


M

ANAGE

D

EVICES

W

INDOW

Times reported by IP Gateways are not synchronized

Possible Cause

A time server has not been configured correctly.

Corrective Action

See Install Time Server (if needed) on Page 11 of this document.

PTT

D

EVICES

USB PTT Device does not activate the on-screen PTT button

Possible Cause

PTT device is not connected to the Dispatch Client PC.

Corrective Action

Ensure that PTT device is connected to Dispatch Client PC.

Possible Cause

Dispatch Client is not configured for PTT device.

Corrective Action

Configuration for USB PTT devices can be found when in the Edit mode by clicking

Dispatch Settings

under

the

Options

menu, then choosing the

USB Devices

folder.

PTT Device initiates a call, but call ends abruptly after 3 seconds

Possible Cause

Transmit audio is not being received by TurboVUi IP Gateway.

Corrective Action

Ensure that microphone is connected to PC, and is selected in the

Audio Presets

list, found in the

Options

menu.