System considerations, Turbovui system planner template, Gps mapping support – CTI Products TurboVUi Dispatch Client Software User Manual

Page 9: Group call support, All-call support, Turbovui version match, Mototrbo control station radio version, Connect plus systems, Pc settings for power and display, Power settings

Advertising
background image

TurboVUi Dispatch

Software Installation and Configuration Guide

9

S

YSTEM

C

ONSIDERATIONS

TurboVUi System Planner Template

Use the System Planner Template at the end of this document to record device names, passwords, and IP addresses.

TurboVUi IP Gateway and MOTOTRBO XPR4550 Configuration

Before installing the TurboVUi Dispatch Client, the TurboVUi IP Gateway(s) must be configured using the ICU.exe
utility (IP Configuration Utility) and installed on an IP network. In addition, the XPR4550 Control Station(s) must be
configured using Motorola’s CPS utility (Customer Programming Software). See the TurboVUi IP Gateway Installation
Guide S2-61534
for more details on the following topics.

GPS Mapping Support

Note: GPS Mapping is not available in the TurboVUi Voice version.

Mapping of subscriber radios requires the following:

TurboVUi IP Gateways must have GPS enabled using ICU.exe

Subscriber radios must have GPS and ARS enabled using CPS

Group Call Support

Group IDs (Call ID) must be added to the Contacts folder in CPS.

All-Call Support

An All-Call group must be added to the Contacts folder in CPS.

TurboVUi Version Match

TurboVUi Dispatch Clients and TurboVUi IP Gateways must have compatible versions in order to communicate with
each other. Compatibility can be ensured when the first two digits of the version match. (The third digit indicates a minor
revision, and does not need to match.)

MOTOTRBO Control Station Radio Version

The MOTOTRBO control station connected to the TurboVUi IP Gateway

must have firmware version 1.6.x or later

.

Connect Plus Systems

For Connect Plus systems, the MOTOTRBO control station connected to the TurboVUi IP Gateway

must have the

following:

Firmware version 2.2.x or later, and

Connect Plus Option Board with firmware version 1.3.x or higher.

PC Settings for Power and Display

Power Settings

The Power Settings should be adjusted so that the PC never hibernates or sleeps. Use the

Power Options

item in the

Control Panel

to make these adjustments.

Display Properties

The TurboVUi Dispatch client has been designed to be used with display monitors with the following display
properties:

Font Size – Normal

DPI - Normal (96DPI)

Altering the above settings may cause the TurboVUi Dispatch client to be displayed improperly.

Advertising