January, 200 4
412 O pe rator And

455 D Control Panel I nst allatio n M anual

T

HE

455 D C

ONTROL

P

ANEL

I

NSTALLATION

I

NSTRUCTIONS

I

NDICATOR

-L

ICHT

:

If 0 is selected, the output func-
tions as a standard indicator-light
(lit at opening and pause, flashing

at closing, and off when gate
closed). Time can be adjusted
from 0 to 59s in 1s increments,

and from 1.0 to 4.1 min. in 10s
steps.

0 = Standard Indicator-Light

From 1 to 4.1 = Timed Output

C

LOSING

P

HOTOCELLS

REVERSE

AT

RELEASE

:

Enable this function if

you want the closing photocells to

stop the gate and reverse it after
the beam is cleared. Default setting
is immediate reverse.

Y = Enable

No = Disabled

A.D.M.A.P. F

UNCTION

:

If this function is enabled, the
safety devices to comply with
French standard NFP 25/362.

Y = Enable

No = Disabled

A

SSISTANCE

R

EQUEST

(

COMBINED

WITH

NEXT

FUNCTION

):

If acti-

vated, at the end of countdown

(settable with the next function, i.e.
“Cycle programming”) it effects 8s
of pre-flashing at every Open pulse

(job request). Can be useful for
setting scheduled maintenance
jobs.

Y = Enable

No = Disabled

C

YCLE

P

ROGRAMMING

:

For setting count down of system
operation cycles. Settable (in thou-
sands) from 0 to 99 thousand cy-

cles. The displayed value is up-
dated as cycles proceed. This func-
tion can be used to check use of

the board or to exploit the
“Assistance Request” function

.

E

XTRA

W

ORK

T

IME

:

When operating, if reversing occurs,
and if the leaf does not reach its
end contact point, you can activate

this function to increase work time.

Y = A

CTIVE

N

O

= D

ISABLED

E

XIT

P

ROGRAMMING

:

Exit from programming.

F

AIL

S

AFE

:

If this function is activated,
it enables a function test of
the photocells before any

gate movement.

Y = Enable

No = Disabled

P

RE

F

LASHING

(5

S

):

5s before start of move-
ment.

Y = Enable

No = Disabled

E

LECTRIC

L

OCK

ON

L

EAF

2:

For using the electric lock on
leaf 2 instead of on leaf 1.

Y = Enable

No = Disabled

ADVANCED PROGRAMMING

Display Function Default

M

AXIMUM

T

ORQUE

AT

I

NI-

TIAL

T

HRUST

:

The motors

operate at maximum

torque (ignoring the torque
setting) at start of move-
ment. Useful for heavy

leaves.

Y = Enable

No = Disabled

L

AST

S

TROKE

AT

C

LOSING

:

The motors are activated at
full speed for 1s to facili-
tate locking of the electric

lock.

Y = Enable

No = Disabled

R

EVERSING

S

TROKE

:

Before opening, while the
gate is closed, the motors
thrust to close for 2 s thus

facilitating release of the
electric lock.

Y = Enable

No = Disabled

L

EAF

2 O

PENING

D

ELAY

(2

S

):

Enables delayed start of

leaf 2, avoiding interfer-
ence between leaves.

Y = Enable

No = Disabled