ROUBLESHOOTING

P

ROBLEM

: T

HE

GATE

DOES

NOT

RESPOND

TO

AN

ACTIVATING

SIGNAL

.

S

OLUTION

:


You should have at least one operator wired to

terminals 1,2 and 3.

Be sure that you have the motor start capacitors wired in

terminals 2 and 3, 5 and 6 with the directional leads.

Be sure that the torque/force setting is at the maximum

setting of 50 in programming for hydraulic operations.

Verify that the LEDs FSWOP, FSWCL, and the STOP are

illuminated. If they are not illuminated, be sure that you
have closed circuits in the stop and reversing inputs.

Verify that your activating device works properly. OP_A
should illuminate when you signal the gate to open. If
OP_A does not illuminate when you signal the gate, then

the problem may be in your activating device. Short
across terminals 9 and 14. If the short causes the gate
to open, then the problem is in the activating device.
Repair or replace the device

.

P

ROBLEM

: T

HE

GATE

DOESN

'

T

OPEN

(

OR

CLOSE

)

THOUGH

THE

MOTORS

ARE

RUNNING

.

S

OLUTION

:

Make sure that the motor is running in the right
direction, and make sure the Manual Release
mechanism has fully engaged the system.

P

ROBLEM

: T

HE

GATE

OPENS

BUT

DOES

NOT

CLOSE

.

S

OLUTION

:

Make sure you have selected the desired operating
mode.

Verify that the reversing devices are working properly.
FSWOP and FSWCL should be illuminated except when a
reversing device is triggered. If either does not

illuminate, then one of your reversing devices is
preventing the gate from responding to your signal.

Check your reversing devices.


If no reversing devices are installed, make sure a circuit

is installed between appropriate terminals.

P

ROBLEM

: T

HE

GATE

DOES

NOT

FULLY

OPEN

(

OR

CLOSE

).

S

OLUTION

:


Check the operator's open/close time selection. You
should set a time that is just longer than the rated

speed of your model of operator. For example, because
the 412 CBAC has a rated opening time of 13 sec, you
should set the time at 20 or 25 seconds.


Check to see that there are no obstructions in the path
of the gate or that the hinges are not binding.

P

ROBLEM

: T

HE

OPERATOR

DOESN

'

T

WORK

SMOOTHLY

AND

THE

GATE

JERKS

AS

IT

OPENS

AND

CLOSES

.

S

OLUTION

:


Make sure the Manual Release Mechanism has fully

engaged the worm screw operation of the operator.

Make sure that a flexible gate leaf is not the problem. If

the gate leaf flexes, then stiffen the gate or use a slower
operator.

WARNING! Before you do any work on the control panel,

be sure to turn off the main power.

NOTE: Any control panel specific information in the following applies to the 455 D control panel only.