455 d c, Ontrol, Anel – Controlled Products Systems Group 104470 User Manual

Page 23: Nstallation, Nstructions

Advertising
background image

Page 23

January, 200 4
412 O pe rator And

455 D Control Panel I nst allatio n M anual

T

HE

455 D C

ONTROL

P

ANEL

I

NSTALLATION

I

NSTRUCTIONS

The procedure has ended and the gate is ready to
operate, using default slow down automatically set

by the control panel.

C

OMPLETE

L

EARNING

N

OTES

:

If only one gate operator (1) is used, you
must go through the entire programming

procedure, as if you were programming a
gate operator (2). When the gate operator
(1) has finished opening, supply 5 open

commands until the gate operator begins
to close, and then resume normal
operations.


Close the gates, enter “B

ASIC

P

ROGRAMMING

, select

the TIME LEARNING function and press the + push-

button for more than 3 seconds: the display begins
flashing and leaf 1 begins opening movement. The
following functions can be commanded by the OPEN

A command (by radio control or key push-button):

When gate operator (1) reaches the
position that you want it to slow down, an

open command must be given to start the
slow down phase. When the gate operator
reaches its positive stop, the operator will

automatically shut off.

An open command must be given to start
opening gate operator (2).

When gate operator (2) reaches the
position that you want it to slow down, an
open command must be given to start the

slow down phase. When the gate operator
reaches its positive stop, the operator will
automatically shut off.

An open command must be given to start
closing gate operator (2).

When gate operator (2) reaches the position
that you want it to slow down, an open
command must be given to start the slow
down phase. When the gate operator reaches

its positive stop, the operator will
automatically shut off.

An open command must be given to start
closing gate operator (1).

When gate operator (1) reaches the position
that you want it to slow down, an open

command must be given to start the slow
down phase. When the gate operator reaches

its positive stop, the operator will
automatically shut off.

The display stops flashing and the gate is ready for
normal operation.

N

OTES

:

The open command to slow down the gate
should be given before the gate reaches the

positive stop to prevent the gate from hitting
the stop at full speed. The positive stop could
be mistaken for an obstacle and then upon

hitting it, the gate(s) would automatically
reverse on contact.

A

UTOMATED

S

YSTEM

T

EST

When you have finished programming, check if the
system is operating correctly.


Most important of all, check that the force is adequately
adjusted and that the safety devices are operating

correctly.

If pressure adjustments on hydraulic operators are not

set before programming. It may need to be
reprogrammed for desired results.