3b. Wiring (pre-wired).

‡ Route wire from wall to Safe-T-Beam

®

sensors

(Fig. 4-5b).

‡ Splice pre-wiring to shortened sensor wire,

match wire pairs dash-to-dash and
plain-to-plain.
- Trim sensor wire to approximately one foot

(1 ft) from sensor.

- Split and strip ends of sensor wires and

pre-wired wires (Fig. 4-7).

- Splice wires together with (provided)

wire nuts.

‡ Route wire from ceiling to power head

(Fig. 4-5b).

‡ Securely fasten wires where they exit

wall and ceiling as you go.
– Use insulated staples.
– Staples should be snug only.

4. Split and strip ends of sensor wires (Fig. 4-7).

NOTE: For rear cover locate Box 4.

5. Attach Safe-T-Beam

®

wire to power head wire

terminal.

‡ Route Safe-T-Beam

®

wires through wire guide.

– Insert wire into terminal holes and lightly press

in the orange locking clips above each terminal
hole. (You can use a pencil or small
screwdriver to comfortably reach in and lightly
press down locking clips.) Insert white wires to
'even' numbered terminal holes and striped
wires into 'odd' terminal holes (Fig. 4-5b).

– Confirm wire lock by lightly tugging on the wire.

The wire should remain in the terminal hole.

‡ Install rear cover. The rear cover is the same

color as the power head clips and body
(Fig. 4-9).

‡ Do not install the white (lamp) cover at this time.

NOTE: Safe-T-Beam

®

alignment check must be

performed following connection to electrical
power (see page 19). DO NOT PLUG IN YET!

Staples which are too tight can cut or pinch wires.
Cut or pinched wires can cause the Safe-T-Beam

®

System to stop working. When using the insulated
staples, make sure you fasten them only as tightly
as needed to hold the wire snugly.

CAUTION

FIG. 4-7
Splitting
and stripping

.

FIG. 4-6 Wire routing

.

Wire

Wire

Source or Sensor

Invisible Light Beam

Protection Area

Insert Wire

Into Connector

Use this

wire routing

if NOT pre-wired

1

2

3

4

Terminal

Holes

Locking

Clips

5

6

+ –

P

B

Infrared Sensor

1

2

3

4

5

6

FIG. 4-8

Insert wires

.

(Power Head With Rear Cover Removed)

FIG. 4-5b Pre-Wired source and sensor wiring

methods

.

or

6 5 4 3 2 1

6 5 4 3 2 1

Sensor

Source

n

e

e

r

G

d

e

R

Power
Head

Dashed Line = striped wire

Solid Line = white wire

Dashed Line = striped wire

Solid Line
= white wire

Wall

Wall

Ceiling

1/2"

2"

Cover clips

FIG. 4-9 Install rear cover

.

Insulated

Staple

Wire Nut

Source or Sensor

Advertising