TRAVEL LIMITS

NOTE: If shuttle/bullet has NOT been engaged to carriage, do so now.

See page 17.

NOTE: Before setting limits confirm wall console red indicator light

(or backlight) is ON. If not illuminated, check for correct wiring or the

Sure-Lock switch may be activated.

Closing Garage Door (Down Limits)

NOTE: You have 30 seconds to execute each step. If you see two

solid red or flashing LEDs on the Powerhead, you have run out of

time and must go back to the beginning of the step and start over. You

can restart as many times as necessary to complete each step.

(continued next page)

• Make sure doorway is in view and clear of obstacles and

people to avoid injury or damage to property.

DO NOT operate this unit from wall console before LIMITS
are set. Severe damage to the opener can occur.

• The shuttle

MUST be engaged to carriage BEFORE setting limits.

See Installation Poster (if provided) or call Customer Service at

1-800-35GENIE or visit www.geniecompany.com

WARNING

1

1

2

1

Lift the door open by hand until the shuttle/bullet

engages the carriage on the rail.

PROGRAM

SET

+

3

Release

down arrow button (-) and the long LED

will begin flashing.

PROGRAM

SET

+

PROGRAM

SET

+

HOLD

4

Press and hold the

down arrow button (-) until

garage door is fully closed on floor, then release.

PROGRAM

SET

PROGRAM

SET

+

HOLD

2 seconds

HOLD

2 seconds

2

Press and hold the

down arrow button (-) for

2 seconds until the long LED comes on blue

(round LED remains off).

Required Programming