R quired pr ramming, Required programming, Wall console / overview – Controlled Products Systems Group 4024 User Manual

Page 8: Series iii wall consoles with black buttons

Advertising
background image

R quired Pr ramming

Required Programming

3

MODEL AC SR3

THE GENIE COMPANY

FCC ID: B8Q AC SR3

Residential Door Operator

IC: 2 33A-CS 1D

120V. 60HZ. 5A

S/N:10XXXX XXXXXXX

STB

BWC

IWC

NOT

USED

NOT

USED

NOT

USED

NOT

USED

FROM STBs

FROM WALL

CONSOLE

STB

BWC

IWC

FROM STBs

FROM WALL

OM STB

CONSOLE

B/W

W

Open/Close Button

Opens and closes door from inside garage.

Sure-Lock™ Button

– LOCK disables controls

after door is completely

closed.

– UNLOCK allows controls to

work normally.

Indicator Light

–Red indicator light is

always ON.

–When Sure-Lock™ is ON,

the indicator light flashes.

Independent Light Control Button

Controls door opener lights from inside garage.

To powerhead

To powerhead

B/W

W

Open/Close Button

Opens and closes door from inside garage.

Sure-Lock™ Button

– LOCK disables controls after

door is completely closed.

– UNLOCK allows controls to

work normally.

Indicator Light

–Red indicator backlight is ON.

–When Sure-Lock™ is

ON, the indicator light is OFF

Independent Light Control Button

Controls door opener lights from inside garage.

To powerhead

To powerhead

WALL CONSOLE / Overview


This opener has a serial
number sticker in which
the serial numbers begin
with 10 or higher.

Wall consoles from other manufacturers may not work with openers
of these serial number groups. Use only the wall console provided with
this unit. Each wall console has three buttons.

In your carton you will find one of the following

wall consoles:

Series II Wall Consoles with White Buttons

Indicator Light
Large white button will display Red when wall console is properly
wired and Sure-Lock

is OFF. When Sure-Lock

is ON, this light is off


Open/Close Button
Use this button to open or close garage door. When Sure-Lock™ is
ON, the Open/Close button will CLOSE the door only.

NOTE: Constant button pressure in the CLOSE mode will override

STB fault in the powerhead and close door.


Independent Light Control Button
Use this button to turn powerhead lights ON. Powerhead lighting will
remain ON until this button is pressed again or a door action has been
completed.

NOTE: If opener has a Motion Detector sensor, it will keep powerhead

lights ON as long as motion is detected.

Sure-Lock

Button

When Sure-Lock

is ON, the powerhead cannot be activated by the

wall console or a remote.
• Press and release (or until red light goes off) to activate Sure-Lock

.

• Press and release to turn Sure-Lock

OFF.

Series III Wall Consoles with Black Buttons

Indicator Light
Indicator light will display Red when wall console is properly wired and
Sure-Lock

is OFF. When Sure-Lock

is ON, indicator light flashes.


Open/Close Button
Use this button to open or close garage door. When Sure-Lock™ is
ON, the Open/Close button will CLOSE the door only.

NOTE: Constant button pressure in the CLOSE mode will override STB

fault in the powerhead and close door.


Independent Light Control Button
Use this button to turn powerhead lights ON. Powerhead lighting will
remain ON until this button is pressed again or a door action has been
completed.

NOTE: If opener has a Motion Detector sensor, it will keep powerhead

lights ON as long as motion is detected.

Sure-Lock

Button

When Sure-Lock

is ON, the powerhead cannot be activated by the

wall console or a remote.
• Press and hold for 5 seconds (or until Indicator Light flashes) to
activate Sure-Lock

.

• Press and release to turn Sure-Lock

OFF.

TIP

8

G999-393 Manual-ScrewBeltChain-EN indd 8

7/13/12 10 17 AM

Advertising