Optional Color CCTV Camera

Linear’s Model CCM-1 (P/N ACP00904) CCTV camera can be installed
inside the AE1000Plus Entry System. The camera provides a video
signal for viewing the area in front of the entry system.
The CAMERA connector is used to connect the camera to the
AE1000Plus. The 4-conductor cable routes power to, and video from the
camera.
The VIDEO jack is the camera output for connection to a video cable with
a Type “BNC” connector. Up to 400 feet of 75-ohm RG-59 video cable can
be used. Longer cable runs may require the use of a video amplifi er.

Camera Installation

1. Remove the two plate locknuts from the camera mounting studs

above the right keylock on the AE1000Plus faceplate.

2. Remove the cover plate.
3. Remove the protective backing from the plastic window included

with the camera and install the plastic window onto the studs with
the adhesive side against the door.

4. Remove the lens cap from the camera.
5. Mount the camera assembly on the two studs, with the alignment

hole in the camera bracket towards the top. Secure the camera
with the two locknuts.

6. Connect the camera’s cable to the AE1000Plus CAMERA

connector.

7. Connect the video cable to the AE1000Plus VIDEO connector.
8. Connect the other end of the video cable to the viewing monitor or

the video distribution system.

Optional Postal Lock

A postal lock can be installed in the AE1000Plus Entry System to provide
keyed access for the postal service. The AE1000Plus case is designed to
accept a U.S. Postal Service postal lock. When the postal lock is engaged,
the programmed output relay will activate.

Postal Lock Installation

1. Remove the four locknuts that retain the postal lock switch plate

(above the speaker on the AE1000Plus faceplate).

2. Remove the switch plate, hole cover plate and block from the four

studs. The hole cover plate and block will not be used and can be
discarded.

3. Install the postal lock assembly onto the four studs. The postal

lock’s moving plunger should point towards the middle of the
faceplate (see fi gure).

4. Replace the postal lock switch plate with the microswitch oriented

inward where it will be pressed by the postal lock’s moving plunger
(see fi gure).

5. Secure the postal lock and switch plate with the four locknuts.
NOTE: Be sure the postal lock’s plunger actuates the

microswitch. Adjust the switch plate and the postal lock then test
the action until the microswitch fully actuates.

6. Tighten the four locknuts after the adjustment and testing is

complete.

7. When programming the system, set the postal lock option to

activate the desired relay output.

REMOVE LOCKNUTS

REMOVE PLATE

INSTALL POSTAL LOCK

PLUNGER POINTS
TO LEFT

REPLACE PLATE WITH THE
MICROSWITCH TOWARDS
THE FRONT OF THE CABINET,
REPLACE LOCKNUTS

NOTE: BE SURE THE POSTAL LOCK'S PLUNGER ACTUATES THE
MICROSWITCH. ADJUST THE SWITCH PLATE AND THE POSTAL LOCK
THEN TEST THE ACTION UNTIL THE MICROSWITCH FULLY ACTUATES

4

3

2

1

1

REMOVE PLATE RETAINING NUTS

2

3

4

5

6

7

COVER PLATE

REMOVE THE PLATE

INSTALL THE GASKET

GASKET

REMOVE THE LENS CAP

ATTACH CAMERA WITH TWO NUTS

CONNECT
CAMERA
WIRING
HARNESS

CONNECT
VIDEO
CABLE

HOLE
ON TOP

Advertising