Pbus accessories, Wiegand accessories – Controlled Products Systems Group AE-1000PLUS User Manual

Page 14

Advertising
background image

14

PBUS Accessories

Up to six accessories (keypads, proximity readers, remote receivers) can
be connected to the three PBUS input/output ports. A typical application
for a remote keypad would be to control a second door or gate.
Linear’s PBUS devices compatible with the AE1000Plus are:

• AM-RRR Remote Radio Receiver
• AM-RGR Remote Radio Receiver
• AM-RPR Radio Proximity Receiver
• AM-KP Exterior Keypad
• AM-KPI Interior Keypad
• AM-CRI Card Reader Interface

Conventional cable or commonly available Cat-5e Ethernet cable can be
used to connect PBUS remote devices to the AE1000Plus. When using
Cat-5e cable, note that the PWR and GND connections use two wires
each to enhance the current carrying capacity for powering the remote
device.

Cable choices:

• Cat-5e Ethernet cable for wire runs up to 500'.
• 24 AWG Belden Type 9931 or equivalent for wire runs up to 300'.
• 20 AWG Weico Type 9405 or equivalent for wire runs up to 600'.

1. Mount and install the accessory as described in its instructions.
2. Route cable from the AE1000Plus to the accessory.
3. Set

the

DEVICE ADDRESS rotary switch in the accessory to

a unique address number. When programming the system, the
device address number will identify each PBUS accessory to the
AE1000Plus.

4. Connect the cable to the accessory and the AE1000Plus (see

PBUS wiring diagram).

Wiegand Accessories

The two AE1000Plus Wiegand inputs (WIEGAND A & B) can connect
to a large variety of 26, 30, and 31-bit Wiegand output accessories. The
Wiegand format is a common standard for access control equipment. A
typical application would be to add swipe card or proximity readers to the
system.

NOTE: Depending on the Wiegand accessory used, the LED1,

LED2, and HOLD connections may not be required.

• LED1 output is switched to ground during non-access time.
• LED2 output is switched to ground for one second during access

time.

1. Mount and install the Wiegand accessory as described in its

installation instructions.

2. Route a cable from the AE1000Plus to the accessory.
• For wire runs up to 300 feet use 24 AWG Belden Type 9931 or

equivalent.

• For wire runs up to 500 feet use 20 AWG Weico Type 9405 or

equivalent.

3. Connect the cable to the accessory and the AE1000Plus as shown

in the fi gure.

REMOTE

PBUS

DEVICE

PCLK

DVAL

DAT0

DAT1

GND

PWR

GND

DAT1

DAT0

DVAL

PCLK

PWR

PBUS

TERMINALS

GND

DAT1
DAT0

DVAL
PCLK

PWR

ACCESS

CONTROL SYSTEM

PBUS TERMINALS

REMOTE PBUS

DEVICE TERMINALS

ORANGE &
ORANGE-WHITE

BROWN &
BROWN-WHITE

GREEN-WHITE

GREEN

BLUE

BLUE-WHITE

GREEN-WHITE

GREEN

BLUE

BLUE-WHITE

CAT-5e

4-UTP CABLE

UP TO 500 FEET PER DEVICE

NOTE: UP TO SIX PBUS DEVICES MAY BE CONNECTED

TO THE THREE SETS OF PBUS TERMINALS

GND
DAT1
DAT0
DVAL
PCLK

PWR

CAT-5e WIRING EXAMPLE

ORANGE &

ORANGE-WHITE

BROWN &

BROWN-WHITE

REMOTE

WIEGAND

DEVICE

LED2

HOLD

LED1

DAT1
DAT0

GND

DAT0

DAT1

LED1

HOLD

LED2

GND

WIEGAND

TERMINALS

PWR

PWR

NOTE: THE LED1, LED2, AND HOLD
CONNECTIONS MAY NOT BE REQUIRED
DEPENDING ON THE WIEGAND DEVICE USED

Advertising