Ampro Corporation Single Board Computer Littleboard 550 User Manual

Page 51

Advertising
background image

Chapter 3

Hardware

LittleBoard 550

Reference Manual

45

Pin #

Pin #
DB9

Signal

Description

16

8

CTS2*

RX2+

Clear To Send 2 – Indicates external serial communications device is
ready to receive data. Used as hardware handshake with RTS2 for low
level flow control.
RX2+ – If in RS485 or RS422 mode, this pin is Receive Data 2 -.

17

4

DTR2* Data Terminal Ready 2 – Indicates Serial port 2 is powered, initialized,

and ready. Used as hardware handshake with DSR2 for overall readiness
to communicate.

18

9

NC

Not Connected (Ring Indicator 2)

19

5

GND

Ground

20

NC

NC

Not connected

Notes: The shaded area denotes power or ground. Signals are listed in the following order RS232 and

RS485/RS422.

Table 3-15. Serial B Interface Pin/Signal Descriptions (J13)

Pin #

Pin #
DB9

Signal

Description

1

1

(COM3)

DCD3* Data Carrier Detect 3 – Indicates external serial communications device

is detecting a carrier signal (i.e., a communication channel is currently
open). In direct connect environments, this input will be driven by DTR3
as part of the DTR/DSR handshake.

2

6

DSR3* Data Set Ready 3 – Indicates external serial communications device is

powered, initialized, and ready. Used as hardware handshake with DTR3
for overall readiness to communicate.

3

2

RXD3
RX3-

Receive Data 3 – Serial port 3 receive data in
RX3- – If in RS485 or RS422 mode, this pin is Receive Data 3 -.

4

7

RTS3*

TX3+

Request To Send 3 – Indicates Serial port 3 is ready to transmit data.
Used as hardware handshake with CTS3 for low level flow control.
TX3+ – If in RS485 or RS422 mode, this pin is Transmit Data 3 +.

5

3

TXD3
TX3-

Transmit Data 3 – Serial port 3 transmit data out
TX3- – If in RS485 or RS422 mode, this pin is Transmit Data 3 -.

6

8

CTS3*

RX3+

Clear To Send 3 – Indicates external serial communications device is
ready to receive data. Used as hardware handshake with RTS3 for low
level flow control.
RX3+ – If in RS485 or RS422 mode, this pin is Receive Data 3 -.

7

4

DTR3* Data Terminal Ready 3 – Indicates Serial port 3 is powered, initialized,

and ready. Used as hardware handshake with DSR3 for overall readiness
to communicate.

8

9

RI3*

Ring Indicator 3 – Indicates external serial communications device is
detecting a ring condition. Used by software to initiate operations to
answer and open the communications channel.

9

5

GND

Ground

10

NC

KEY/
NC

Key
Not connected

Advertising