Cause action – Nilfisk-ALTO 748 L User Manual

Page 29

Advertising
background image

CLARKE TECHNOLOGY

Operator's Manual -

SCRUBTEC 770 / 784 / 795

SCRUBTEC 770 / 784 / 795

SCRUBTEC 770 / 784 / 795

SCRUBTEC 770 / 784 / 795

SCRUBTEC 770 / 784 / 795

- 29 -

SCRUBTEC 770 L, 784 L, 795 L

Common Error Codes

3100
3101
3102
3103
3104
3105

7600

7603

7800

7802

9000

2F01

Probable short circuit of
output device.

Open circuit on brush motors
or brush motor wiring.

Possible short circuit on
brush motors or wiring.

Open circuit on traction motor.

Traction motor current has
exceeded current limit for the
fold back time.

Brushes not fitted.

Drive system activated prior
to turning key switch "ON".

Check the traction, brush and vac motor
connections on the trio and check wiring
from these connectors down to the
traction, brush and vac motors.

Check the brush motor connection on
the trio and check the wiring from this
connector down to the brush motor.

Check the traction motor connection on
trio and wiring down to motor.

Excessive driving up an incline, or
machine driven up against an obstacle
or step.

Brushes

Release traverse switch and reactivate.

ERROR

CODE

CAUSE

ACTION

NOTICE: IF ERROR CODE/FAULT OCCURS TURN KEY SWITCH OFF AND THEN BACK ON.

For further codes and explanations, contact a ALTO Service Center.