Y MATHEWS GRAPHIC DESIGN

460-04-03

VENTILATION

WARRANTY

Units carry a 15 year warranty on

the heat recovery core and a 2

year replacement parts warranty.

OPTIONS AND ACCESSORIES

28 998: 60 MIN. REMOTE TIMER
28 882 DEHUMIDISTAT
- Activates high speed when indoor

humidity rises above set point on control

Note: Manufacturer

reserves the right to change

specifications without notice.

All units conform to CSA and UL Standards

SPECIFICATIONS

General: Unit shall be completely wired and includes blowers,

filters, heat exchange cores and control panel.

Cabinet: 29

7

/

8

” x 41

1

/

2

” x by 24

5

/

8

” H (760 x 1055 x 625 mmH).

Constructed of 20 gauge prepainted galvanized steel (G60).

Interior lined with foil faced Insulation where surface is ex-

posed to cold air. Access door is hinged and latch. Disconnect

switch engaged by door panel. Condensate pan has drain

connections.

Heat Exchange Core: Three modules, aluminum plate heat ex-

change core assembly.

Air filter: Six washable filters.
Motors:

Two efficient three speed PSC double shafted motors 120

VAC, 4 Amps each (8.1 Amps total on high speed),
1/4 HP, 1625 RPM. Watts - total on high speed - 972.

Blowers: Centrifugal type rated at 1200 CFM (566 L/s) free air

delivery. Each air stream has one double shafted motor driving

a centrifugal blower. Rubber isolated mounts.

Controls: Illuminated power switch, 3 speed blower control, low

voltage (24 VAC) terminals for connection of remote controls

and defrost light indicating automatic operation.

Defrost:

Pool and Defrost air bypass routes air to defrost core. Light

indicates when automatic damper defrost occurs (preset at

27°F (-3°C).

Duct Connections: Five 20" X 8" (508mm X 200mm H).
Drain Connections: Two 1/2" O.D.

Mounting: Unit to be set in support brackets hung by threaded rod

type apparatus. (Brackets and rod not provided).

Weight: 191 lbs (87 kg)
Shipping Weight: 215 lbs (98 kg)
Manufacturer:

American ALDES Ventilation Corp.

4537 Northgate Court, Sarasota, FL 34234

DIMENSIONS