31. 24VDC Terminals

24VDC is available on these terminals and can supply current up to 250mA. This DC output is useful

for supplying DC voltage to trigger Atlas PA series attenuators.

Note: Do not short these terminals together or ground them.

32. Relay

The AA120M supplies contact points to trigger an external component. The SPDT (single pole double

throw) set of relay contacts have (C) Common, (NO) Normally Open, and a (NC) Normally Closed

contacts available on these terminals - 500mA Max. The relay can be activated via two methods,

remote contact closure or VOX mute. Refer to Dipswitch #4 "Relay Act" for relay trigger selection.

The

(CC) Contact Closure setting works in conjunction with the Remote Mute feature. Refer to section

27

"REMOTE MUTE" for detailed information.

The

(VOX) setting works in conjunction with a Mute Send from an assigned Input channel. Refer to

section 17 the "MUTE SWITCH" for detailed information. This feature is also known as VOX.

33. Loudspeaker Terminals

For loudspeaker connections, connect as follows or proceed to the setup section for typical wiring

diagrams.

COM - Speaker common or negative connection
8

OHM - Connect to direct coupled loudspeakers

25V - Connect to transformer coupled, 25V loudspeakers with a total load impedance of

no less than 5.2Ω

70V - Connect to transformer coupled, 70.7V loudspeakers with a total load impedance of

no less than 41.6Ω

100V - Connect to transformer coupled, 100V loudspeakers with a total load impedance of

no less than 83Ω

34. Circuit Breaker

The circuit breaker is designed to trip and shut down the AA120M "Unswitched Outlet". After correcting

the cause of the breaker tripping, reset the breaker by pushing in on the tab.

Vox Mute

Vox Mute

Input 5

Level

Zone 3

Level

Zone 2

10

0

10

0

10

0

10

0

10

0

10

0

10

0

G

+

G

+

G

+

G

+

Unswitched Outlet

120V AC 60Hz

Max 500W

Outlet Breaker

125V AC 4A
Push Reset

120V AC 60Hz 300W

100V

70V

25V

¡

8

Com

24V DC 200mA

Relay

+

NC

C

NO

+

+

Zone 2 Out

1W 8

Zone 3 Out

¡

¡

600

Remote Mute

VCA

+

G

Sel

Bridge

In/Out

Input 6

Level

Zone 3

Level

Zone 2

10

0

10

0

Sens

Input 4

Trim

Input 3

Trim

Input 2

Trim

Input 1

Trim

Mute

10

0

10

0

10

0

10

0

10

0

10

0

10

0

Send

Off

Rcv

Send

Rcv

Off

Send

Off

Rcv

Send

Off

10

0

Zone 2 Level

Zone 3 Level

Input 3

Input 2

Input 1

Pwr In

Tape Out

1 2 3 4 5 6 7 8 910

R

Line Out

L

Input 5

Pre Out

Input 6

Input 4

Zone 2 Level

Zone 3 Level

Zone 2 Level

Zone 3 Level

Zone 2 Level

Zone 3 Level

£Ид£К>VŽÊV>ЮК Ы`°]К ˜˜ˆГ]К/8КЗx££™К
­nдд®ÊnÇȇООООКМ>Г-œХ˜`°Vœ“

77'(&C

7jbWiIekdZ77I[h_[iC_n[h7cfb_\_[h

Speaker Output 120W

Vox Mute

VoxMute

Send

Off

Rcv

CLASS 2 WIRING