Owner's manual, Aa120m mixer amplifier, Quick start examples – Atlas Sound AA120M User Manual

Page 15: Example 1

Advertising
background image

Specifications are subject to change without notice

AtlasSound.com

1601 JACK MCKAY BOULEVARD ENNIS, TEXAS 75119 U.S.A. • TELEPHONE: (800) 876-3333 • FAX: (800) 765-3435

©2006 ATLAS SOUND LP

Printed in U.S.A.

00106

ATS002179 RevA 01/06

PP

OWNER'S MANUAL

AA120M MIXER AMPLIFIER

15

QUICK START EXAMPLES

Example 1 - System Paging, BGM, and MOH with Emergency Page Override
When a page signal is received from INPUT 2 and the RMT MUTE terminals are shorted, the page will be
the only audio heard in the main system because BGM will be muted. If an emergency page comes into
INPUT 1, all inputs will be muted except for the emergency page. Note: Zone 3 MOH output will not be
muted or affected by either page scenario.

• Connect a paging mic to INPUT 1. This will be the priority emergency page over ride mic input.

Note:

The

INPUT

1

Trim and Sens will need to be adjusted after all the settings and connections

have

been

set.

• Connect a paging mic with a switch to INPUT 2.

• Connect the switch wires from the mic connected to INPUT 2 to the "RMT MUTE" terminals. Note:

The polarity on the switch to the terminals does not matter.

• Set Dipswitch 9 and 10 to the "MIC" position.

• Set INPUT 1 to Mute Send.

• Set INPUT 2 to Mute RCV.

• Connect a BGM player to INPUT 5. Note: The input gain of this channel may need to be changed for

proper level balance. Dipswitch 6 allows you to select between a 100mV or 300mV input sensitivity.

• Connect Zone 3 output to the MOH input on your telephone system. Adjust Input 5's Zone 3 output

level as needed.

Dipswitch Settings

Dipswitch 1 - OFF

Dipswitch 2 - OFF (Not affected)

Dipswitch 3 - Depends on mic type

Dipswitch 4 - OFF (Not affected)

Dipswitch 5 - OFF (Not affected)

Dipswitch 6 - Set to the required gain

Dipswitch 7 - OFF

Dipswitch 8 - OFF

Dipswitch 9 - ON (Mic)

Dipswitch 10 - ON (Mic)

Example 1

Vox Mute

Vox Mute

Input 5

Level

Zone 3

Level

Zone 2

10

0

10

0

10

0

10

0

10

0

10

0

10

0

G

+

G

+

G

+

G

+

Unswitched Outlet

120V AC 60Hz

Max 500W

Outlet Breaker

125V AC 4A
Push Reset

120V AC 60Hz 300W

100V

70V

25V

¡

8

Com

24V DC 200mA

Relay

+

NC

C

NO

+

+

Zone 2 Out

1W 8

Zone 3 Out

¡

¡

600

Remote Mute

VCA

+

G

Sel

Bridge

In/Out

Input 6

Level

Zone 3

Level

Zone 2

10

0

10

0

Sens

Input 4

Trim

Input 3

Trim

Input 2

Trim

Input 1

Trim

Mute

10

0

10

0

10

0

10

0

10

0

10

0

10

0

Send

Off

Rcv

Send

Rcv

Off

Send

Off

Rcv

Send

Off

10

0

Zone 2 Level

Zone 3 Level

Input 3

Input 2

Input 1

Pwr In

Tape Out

1 2 3 4 5 6 7 8 910

R

Line Out

L

Input 5

Pre Out

Input 6

Input 4

Zone 2 Level

Zone 3 Level

Zone 2 Level

Zone 3 Level

Zone 2 Level

Zone 3 Level

£Ид£К>VŽÊV>ЮК Ы`°]К ˜˜ˆГ]К/8КЗx££™К
­nдд®ÊnÇȇООООКМ>Г-œХ˜`°Vœ“

77'(&C

7jbWiIekdZ77I[h_[iC_n[h7cfb_\_[h

Speaker Output 120W

Vox Mute

VoxMute

Send

Off

Rcv

CLASS 2 WIRING

Vox Mute

Chime Module

To 70V Speakers

Background

Music Noise

To Music on

Hold Port

From Input 2

Paging Mic Switch

Emergency

Paging Mic

Front Desk

Paging Mic

To Remote

Mute Terminals

Advertising