Mallory Ignition ACCEL timing computer 49340 User Manual

Page 11

Advertising
background image

T

HE

MAP

(M

ANIFOLD

A

BSOLUTE

/ A

IR

P

RESSURE

)

S

ENSOR

C

ONNECTOR

he MAP Sensor’s signal to the Timing Computer is through the flat, 3-pin connector.

nstall a 2-

BAR

MAP Sensor, according to its own instructions and plug the Timing

Computer’s male connector into the sensor’s 3-pin female port.

he MAP Sensor reads intake manifold pressure. This makes it possible for the Timing

Computer to adjust to a predetermined timing curve under Vacuum or Boost conditions.

Use an A

CCEL

/ DFI 2-BAR MAP Sensor, Part# 74776

(No need for a 3-Bar MAP Sensor, even with high boost.)

he MAP Sensor measures pressure. Manifold Absolute Pressure is near 0

BAR

at high

acuum, near 1

BAR

at wide open throttle, and up to 2

BAR

at about 14

PSI

of Boost.

Vacuum sensing provides a linear advance of the Base Timing Curve from 0° to full

dvance during high vacuum conditions.

I

.

E

. You have set Maximum vacuum advance

t 10°. At wide open throttle there is little intake manifold vacuum and ignition timing

ollows the

RPM

curve. At light load (.5

BAR

, about 15 inches of Hg

) the Timing Computer

dds 5° (half the 10° Maximum Timing) to the Base Timing Curve.

Boost retard works the same but in the opposite direction: Suppose you program a Boost

Retard value of 6° at the maximum sensing boost of 1

BAR

(about 14

PSI

). At 0.5

BAR

about 7

PSI

) boost the Timing Computer retards ignition 3° from the Base Timing Curve.

T

HE

S

QUARE

, 4-

PIN

, M

ALE

I

NPUT

C

ONNECTOR

he A

CCEL TIMING

C

OMPUTER

inputs from all kinds of trigger types, except distributor-less,

nd its digital, micro-processor controlled, rev-limiter will be as sensitive as your trigger.

We recommend an A

CCEL

Billetech Distributor or A

CCEL

Crank Trigger. Triggering inputs

re read through the square male connector: W

HITE

wire, or the P

URPLE

and O

RANGE

wires.

Your A

CCEL

+ ignition system should already have this connector in place.

he W

HITE

wire’s input is in the form of

Square Wave. It gets this input from:

• All points ignitions
• Most fuel injections
• Some

HEI

modules

he P

URPLE

and O

RANGE

wires get their

nputs from magnetic pickup or crank-

iggered systems

he P

URPLE

wire is a positive (+) input

nd the O

RANGE

is a negative (–) input.

(See chart for various connections.)

your system uses the W

HITE

wire you

ust isolate and insulate the P

URPLE

nd O

RANGE

wires. If your system uses

he P

URPLE

and O

RANGE

wires you must

olate and insulate the W

HITE

wire.

* Older A

CCEL

Crank triggers may connect W

HITE

to P

URPLE

and B

LACK

to O

RANGE

.

Advertising