A

DJUSTING YOUR

I

GNITION

T

IMING TO

P

ROPER

S

PECIFICATIONS

1

. Start your engine and then press the T

IMING

and VAC ADV keys.

The Timing Computer displays the number of degrees BTDC ignition timing.

2

. Use the

and

keys to select one of the engine timing marks as a value.

Your Timing Computer will use this fixed ignition timing, regardless of
engine speed or other inputs.

3

. Make fine adjustments to your trigger input, with a Timing Light,

so it matches the value on the Timing Computer’s display.

4

. Return the display to Control Mode by pressing the T

IMING

button twice.

R

EV

-

LIMITING WITH THE

T

IMING

C

OMPUTER

our A

CCEL

+ ignition has the final say in rev-limiting, but there are ways you can use

he Timing Computer to rev-limit at a lower engine speed than what has been set in the

gnition box. One way is to retard timing by 10° – 15° at your chosen engine speed, as

hown on Page 7. Another way is program a rev-limit with the Accel Timing Computer.

1

. Press the RPM and VAC ADV keys to get into Programming Mode.

The current value for rev-limit will display.

2

. Use the

and

keys to adjust this value in 100 RPM increments.

(Note: Your A

CCEL

+ ignition rev-limits in 250 RPM increments.)

3

. Press the RPM button twice, to return to Control Mode, and then press SAVE.

C

ONFIGURING

WITHOUT

A

MAP S

ENSOR

lthough we do recommend a MAP Sensor, you can operate without one. For best results

se Magnetic Triggering, or a Points Distributor with mechanical advance locked out.

o not adjust or remove the Vacuum Advance mechanism on the distributor.

1. Program your Base Timing Curve as described on Pg 6.

2. Set VAC ADV and B

OOST

R

ETARD

both to 0°.

3. Press SAVE to store all new values.

U

SING THE DISPLAY AS A

D

IGITAL

T

ACHOMETER

ou can make your Timing Computer display engine RPM by simultaneously pressing

oth the RPM and T

IMING

keys. It will continue displaying as a digital tachometer until

ou enter Programming Mode. When you exit from Programming Mode the LED’s will
nce again display engine timing.

R

ESTORING THE

F

ACTORY

D

EFAULT

S

ETTING

ou may decide, for one reason or another (such as replacing a major engine component)

o restore the Timing Computer’s original Factory Defaults. To restore Factory Defaults:

1

. Turn the power

OFF

.

2

. Press and hold down SAVE and B

OOST

R

ETARD

and apply the power.

When the display reads 1 2 3 0 0 release both keys.

F

ACTORY SETTINGS

:

a default timing curve, no adjustment for additional inputs,

RPM Activated Switch-1 set at 4,500

RPM

, Switch-2 set at 6,500

RPM

,

no rev-limit, Cylinders = 8, Trigger Position set to 36° BTDC.