Figure 3.21: diagnostics dialog box, Table 3.5: diagnostic test details – Avocent AutoView 1515 User Manual

Page 50

Advertising
background image

38

AutoView 1415/1515/2015 Switch Installer/User Guide

NOTE: AVRIQ or IAC modules may appear to be offline while being upgraded.

Figure 3.21: Diagnostics Dialog Box

Next to each item to be tested, you will see a pass (green circle) or fail (red x) symbol display to
the left of each item as that test finishes. The following table details each of the tests

.

To run diagnostic tests:

1.

If the OSCAR interface is not open, press

Print Screen

. The Main dialog box will appear.

2.

Click Commands

-

Run Diagnostics.

A warning message displays indicating that all users will

be disconnected.

Table 3.5: Diagnostic Test Details

Test

Description

Memory Tests

Reports on the condition of the main board RAM

Firmware CRCs

Reports on the condition of the main board RAM

Comm Interfaces

Validates the current firmware images stored in the system’s Flash

Switch Controller test

Verifies the switch matrix controller is accessible and functional

Local Video

Indicates the condition of the local video monitor

On-line Targets

Indicates the total number of currently connected and powered targets

Offline Targets

Indicates the number of targets that have been connected successfully in the
past and are powered down

Suspect Targets

Indicates the number of targets that have been detected, but are either
unavailable for connection or have dropped packets during the ping tests