www.mastercool.com

8

R

NOTE: When the manifold is in the last hour of recording and the user performs a check
status command the 0 that will be displayed shall be flashing to indicate that the recording
capacity is approaching the limit.

EXITING RECORDING MODE

Once sufficient data has been recorded exit the recording mode by pressing and holding
the BLT/REC button for 5 seconds. OFF will appear in the display and then you can release
the button.

R

NOTE: Powering OFF the manifold will also turn off the recording mode.

DELETING RECORDED DATA

NOTE: When the delete recorded data command is performed all data will be erased from
the manifold.
NOTE: The data will not delete if you are in recording mode. Exit record mode in order to
delete the data.
• Once the data in the manifold is no longer of use delete the data by simultaneously
holding down the ENTER + BLT/REC buttons and then pressing the POWER button until
the default screen appears on the LCD.

CLEANING THE SENSOR

(SEE FIG. D)

Observe the gasket after each vacuum. If oil is present, it is possible that there is a
presence of oil in the sensor chamber.
Follow these instructions:
1. Disconnect the sensor chamber from the socket.
2. Remove the gasket & depressor from the assembly to clean.
3. Clean the gasket. Rinse the sensor chamber with acetone. Repeat until the oil is
completely removed. Allow 2 – 4 hours for all of the parts to dry.
4. Reassemble all of the parts and check the unit.

DEPRESSOR
GASKET

1/4” FL-F Swivel Nut

SENSOR TUBE

SENSOR CHAMBER

SOCKET

CABLE

FIG. D

PARTS AND ACCESSORY LIST

42010

Gasket for 1/4” FL

42014

Depressor

85511

3/8” Gasket for Black Hose

99103-SENSOR

Sensor

99903-BLOCK

Block for 99903

99903-PC

PC Board for 99903

99903-PB

Plastic Box

99903-RB

Rubber Boot

98061-SENSOR

Sensor Assembly

98062-001

Vacuum Sensor Cable (only)

99332

1/8 NPT x 1/4 F Flare Swivel Adapter

99903-USB

USB Cable

OPTIONAL ACCESSORIES

52232

Humidity Temperature Meter

52336

Clamp-On Thermocouple (3 ft)

52337

Clamp-On Thermocouple (10 ft)

98062

Complete Vacuum Sensor & Cable Assembly

98210-A

Accu-Charge II Electronic Refrigerant Scale

99333

1/4 FL-M x 1/4 FL-M x 1/4 FL-F Tee

99334-110

110V AC/DC Adapter

99334-220

220V AC/DC Adapter (schuko plug)

WARRANTY

This product warrants against defects in material and workmanship for a period of one
year. This warranty does not cover failure due to abuse, improper usage, or progressive
wear and tear. Warranty becomes valid to the original user, effective on the purchase
date. A copy of an invoice along with a registration card must be sent to 1 Aspen Drive,
Randolph, NJ 07869 to validate the warranty.
For further service please contact (973) 252-9119.