Saving test information (new entry), Looking at previously saved information – Mastercool 52251 A_C SYSTEM ANALYZER User Manual

Page 5

Advertising
background image

5

www.mastercool.com

to system.
• When saturated temperature stabilizes, press

ENTER.

• Press

F2 (NEXT).

• Insert plug from clamp-on thermocouple into type K

thermocouple socket.
• Follow screen instructions to place clamp-on thermocouple.
• When temperature has stabilized, press

ENTER.

• Press

F2 (NEXT).

• Actual Subcool will be displayed.

SAVING TEST INFORMATION (NEW ENTRY)

• Use NEW ENTRY to save testing information under

Customer, Technician, and Date.
To enter a New Customer
• Use power button to turn on A/C Analyzer.
• Use ▲ or ▼ buttons to highlight NEW ENTRY.
• Press

ENTER.

• New Customer will be highlighted.
• Press

ENTER.

• Use ▲ or ▼ buttons to adjust letter or number.

NOTE: Using ▼ button will go directly to numbers.

• Use ► or ◄ buttons to highlight next space.
• When done press

ENTER.

• Use ▲, ▼, ►, or ◄ buttons to enter Technician.
• When done press

ENTER.

• Press

F1 (DONE).

• NEW TEST will be highlighted.
• Press

ENTER.

• Any testing will be recorded under the current date. For

instructions on how to do the testing see Quick Start.
• To see the testing summary press

F2 (DATA) at the end of

each test except DB/WB/RH/DP/Air Vel.
To add a test to an Existing Customer
• Use

POWER button to turn on A/C Analyzer.

• Use ▲ or ▼ buttons to highlight NEW ENTRY.
• Use ▼ or ▲ buttons to highlight existing Customer.
• Press

ENTER.

• NEW TEST will be highlighted.
• Press

ENTER.

• Any testing will be recorded under the current date and

time. For instructions on how to do the testing see Quick

Start.
• To see the testing summary press

F2 (DATA) at the end of

each test except DB/WB/RH/DP/Air Vel.

LOOKING AT PREVIOUSLY SAVED

INFORMATION

• Use

POWER button to turn on A/C Analyzer.

• Use ▲ or ▼ buttons to highlight Customer Search.
• Press

ENTER.

• Use ▲ or ▼ buttons to highlight Customer.
• Press

ENTER.

• Use ▲ or ▼ buttons to highlight Test Number.
• Press

ENTER.

• Saved test data will be displayed.

Advertising