MaxPower Corp GE SG Series 10-150kVA User Manual

Page 4

Advertising
background image

Provides Galvanic Isolation of

the Load

Protects Inverter from Non-

Linear Loads

Protects Inverter from High Inrush Loads

Space Vector Modulation (SVM)
Space Vector Modulation is the next generation of Pulse Width

Modulation (PWM) inverter control technology. SVM uses an

advanced switching technique for PWM driving Insulated Gate

Bipolar Transistors (IGBT).

Advantages

Higher Efficiency: Reduces switching losses and improves

partial load efficiency

Improved Output Performance: Reduces Total Harmonic

Distortion (THD) with non-linear loads and improves transient

response to step loads

Precise Paralleled System Performance: More accurate load

sharing with multiple units operating in parallel

Superior Battery Management (SBM)
Every GE UPS incorporates a standard feature called Superior

Battery Management (SBM) that can be configured to periodically

test the battery system and calculate true battery runtime using

measured values for temperature and load.

Advantages

Works With all Battery Types: Flooded, VRLA NiCad, and

Sodium (GE Durathon)

Online Battery Test: The risk of load loss is prevented by

periodic rectifier/battery testing to insure proper operation

Increases Battery Life: Monitors all key parameters of the

battery plant to maximize reliability and warn of possible

problems

Digital Signal Processor (DSP)
DSP (Digital Signal Processor) performance enables the high

sampling rates required to achieve the appropriate bandwidth

for the current and voltage controls for an efficient double-

conversion UPS.

High speed sampling rate for precise RPA control.

Faster transient response time

Redundant high speed communication

All digital controls for increased reliability and stability

All system control parameters are adjustable from the

front panel

Zig Zag Output Transformer
The ZigZag transformer enables the UPS to run with heavily

unbalanced loads while supplying full kVA output capacity at

100% non-linear load.
The secondary windings of the output transformer form a

ZigZag pattern to cancel triplen (third order) load harmonics.

This reduces neutral conductor loading and losses in all the

conductors and the input transformer.

Innovative Product Technology

SBM - UPS Battery Management and Test

SBM s a comprehensive and programmable management and monitoring system that protects the UPS battery string life.

Batteries are prevented from overcharging and deep discharging.

Calculates true battery autonomy and remaining battery

backup time during utility outage.

Measures the volts per cell of the battery system and

compensates for temperature and load

During UPS startup, the SBM is programmed with specific

battery information

Programmable features allow the user to select the frequency

and type of battery tests that are performed. Frequency range

can be from once per week to annually. Test type range can

be from deep cycle to 3-min discharges.

All tests logged in the UPS events menu and any failure is

reported on the UPS front alarm panel.

All tests done automatically

with the UPS on-line.

Manual tests can be

performed at any time.

Remote programming and

configuration is available

through the SG Series UPS

protection software.