Meriam M2110P SMART PRESSURE GAUGE User Manual

Page 28

Advertising
background image

28


Note: The Smart Gauge comes with 1/8” FNPT pressure port(s). Gauge and Absolute
models only use one pressure port. The unused port vents the enclosure/sensor to
atmosphere. DO NOT REMOVE THE SINTERED PLUG (ALLEN HEAD FITTING).
The Smart Gauge should be panel-mounted or held firmly in one hand while a small wrench
is used to tighten the 1/8” MNPT pipe thread. Do not tighten the fitting without using a
wrench on the manifold.








DN & DI Manifold

DI Manifold

G

I

, C

I

and A

I

Manifold

(Optional Flushing Ports)


Current Loop Model Wiring

+

-

24V

50mA (min)

+24V

+Loop

R

-Loop

-24V

or GRD

Three wire from positive (+) supply: source

24V

50mA (min)

+

-

R

+24V

+Loop

-Loop

-24V

or GRD

Three wire from negative (-) supply: sink

24V

30mA (min)

+

-

24V

+

-

20mA (min)

R

+24V

+Loop

-Loop

-24V

Four wire, non grounded system

Three and four wire 4 to 20 mA loop diagrams

R = Receiving device

Power supplies can

be 15 to 28 Vdc

Advertising