3 loading the compound for modcell – Micromod MOD: 1750N Output holder for MOD 30ML User Manual

Page 22

Advertising
background image

Output Holder Instructions

CONFIGURATION

4.3

LOADING THE COMPOUND FOR MODCELL

The PID_OH compound has a fully functional PID, with I/O and also the logic for bumpless
transfer of output.



If you already have your PID configured, you can delete the blocks that are not required from
this compound after loading.

1. Launch the ViZapp Software and open your workspace, project and the instrument

database.

2. The PID_OH1 compound can only be loaded inside a loop compound. Open the loop

compound where you want to load the PID_OH compound.

3. Select

Project – Gallery – Component Gallery from the menu bar as shown in the

figure below:


Figure 4 .7. Opening the Component Gallery

4. The Component Gallery dialog will be displayed as shown in the next figure. Select the

Compounds tab and click on the PID_OH_MCELL compound from the list of compounds
as shown and then click on the Export button.

4 -8