: The GFCI circuit breaker provides protection only to the circuit

to which it is connected. It does NOT provide protection to any other circuit.

OCCUPANT:

GFCI Breaker

GFCI s are proven lifesavers, however, consumers need to take a few minutes each

month to do this simple test. By taking action, you can help protect your family from

the risk of electric shock.Perform this test on the GFI Breaker each month and record

the date on the chart.

1. With handle B in “ON” position, press PUSH TO TEST button A.

2. Handle B should move to TRIP position, indicating that GFCI

breaker has opened the circuit.

3. To restore power move handle B to “OFF” and the to “ON

Important: If handle B does not move to TRIP position when test

button is pressed, the GFCI breaker protection is not complete. If this happens,

replace GFCI breaker.

Remote Generator Hook Up (optional equipment)

The remote generator hook up will be located on the front plate of the trailer just behind

the LPG bottles. A generator can be plugged into the 110-volt system using this plug

and a power cord supplied separately with this option.

The system includes a automatic transfer switch to prevent a power overload if a

generator is started while the trailer’s 110-volt shoreline is plugged into a 30 amp

service. The transfer switch will automatically switch power from a shoreline source to

a generator when it senses power entering the switch from the generator. When power

is cut from the generator, the switch returns to the shoreline as its power source.

A minimum of 5.5 KW with a 30-amp breaker will be required to sufficiently power the

30 amp service.

INVERTOR (option)

The Inverter powers the TV and one additional labeled 110 volt receptacle. The in-

verter converts 12 volt electricity from your batteries into 110 volt power. The switch

for the inverter is located under the monitor panel. Overloading the inverter will cause

a automatic shut off to activate. Removing the load will allow the inverter to reset.

DOOR BELL

The door bell module is located under the galley flip up shelf on all models except the

34 ‘, which is located under the dinette table. The module uses 4 “C” batteries. The

batteries should be removed during long periods of storage.