MONITOR PANEL

Micropulse Systems Monitor

CATCON PRODUCTS INC.

817-921-2188

[email protected]

The MicroPulse System makes use of a single solid-

state sensor per tank. The MicroPulse sensor measures

the static (head) pressure at the bottom of the tank and

transmits this information to the MicroPulse System

Monitor. Knowing this pressure value, after a one-

time calibration has been performed, the MicroPulse

System will calculate and accurately display the tank

level in 1/8 increment.

A single sensor is installed on the sidewall of each tank,

near the bottom, via a 3/4” female NPT spin-in thread.

The sensor is solid state, there are no moving parts to

wear or maintain. Because the principle of operation

does not involve any electrical current flow through the

tanks contents (conducted or induced), the nature of

the fluid in the tank is unimportant.

The monitor system has been calibrated at the factory

and should never need another calibration. If you feel

the system is not operating correctly, please contact

CATCON Products or a local Airstream dealer. The

following instructions are provided for qualified

service technicians.

MICROPULSE SYSTEMS MONITOR

OPERATION INSTRUCTIONS

This example shows the monitor reporting the

following:

Fresh Water = 1/8 to Empty

Gray Water 1 = Empty to 5/8

Gray Water 2 = 3/4

Black Water = Empty to 5/8

LP Gas = 1/4

Battery = Empty to 5/8

On all diagrams the Letters R=Red, Y=Yellow,

G=Green, Blank=no LED lit.

NORMAL OPERATION

The MicroPulse Monitor will display the condition of

each system at all times. The tricolor LED beside the

system will indicate the condition of the system using

the following color code.

Fresh Water, LP Gas, Battery are as follows:

Green LED = 3/8 to Full

Yellow LED = 1/4

Red LED = 1/8 to Empty

Gray Water, Black Water are as follows:

Green LED = Empty to 5/8

Yellow LED = 3/4

Red LED = 7/8 to Full

TO OBTAIN EXACT READING

To obtain an exact reading of all systems press and

release the status button one time. The monitor will

flash the LED beside the system it is about to report. It

will than display the exact condition of that system by

lighting the bar graph from Empty to Full. The monitor

will display the exact condition of each system and

then return to normal operation mode.

To obtain an exact reading of an individual system press and

release the status button until the LED beside the system

that you want the condition of is lit. Release the status

button and the monitor will display the exact condition of

that system by lighting the bar graph from Empty

Monitor Display

Fresh Water

Gray

Water 1

Gray

Water 2

Black Water

Battery

R

G

G

G

Y

Y LP Gas