0 advanced features and the setup menu for hh9 – Nova-Tech LMI Series HH Metering Pump User Manual

Page 33

Advertising
background image

33

13.0 Advanced Features and the Setup
Menu for HH9

Advanced features such as Batch Accumulate, Computer Interfacing,
and Automatic Voltage Compensation, may be selected and altered
in the Setup Menu of the Series HH9. The following configuration
chart describes each menu item, its description, and available
settings.

Menu

Description/

Item

Function

Setting

Notes

Software Revision

Read Only

1

Batch Accumulate

0 = Disable

Applies to External Multiply mode

1 = Enable

3

Automatic Voltage

0 = Disable

Becomes active two (2) minutes after

Compensation

1 = Enable

power up.

6

Input Pulse Width

0-60

Allows pulse widths of 1 to 60 mSec to be
set. Setting of 0 gives a debounce time of
approximately 1 mSec.

7

Integral Blowdown

0 = Disable

Allows Activation of the integral blowdown

1 = Enable

feature.

8

Integral Blowdown

0 to 255

Set solenoid ON time in seconds.

Solenoid ON Time
(Seconds)

9

Integral Blowdown

0 to 255

Set pump ON time in seconds.

Pump ON Time
(Seconds)

Note:

Allow 15 seconds after programming before disconnecting from power
to ensure latest changes are stored in nonvolatile memory.