5.3

Specifications

5.3.1 Functional

System Design

Measurement Principle

Magnetostrictive time-of-flight

Input

Measured Variable

A return signal is generated from the precise location where the magnetic

field of the MLI float intersects the magnetostrictive wire

Zero and Span

6 inches to 400 inches (15 to 999 cm)

User Interface

Keypad

3-button menu-driven data entry and system security

Indication

2-line

× 8-character display

Digital Communication

F

OUNDATION

fieldbus

, H1 (31.25 kbits/sec)

Interoperability test kit (ITK Revision)

ITK 4.61

LAS capable

Yes, Device type: Linkmaster

Minimum Operating Voltage

9 VDC

Quiescent Current Draw

15 mA

DEV Revision

0X01

Function Blocks

1xRB, 2xAI(s)

Damping

Adjustable 0-25 seconds

Power (Measured at instrument terminals)

Fieldbus General Purpose/Explosion Proof 9 to 32 VDC (17 mA maximum current draw)

FISCO/FNICO

9–17.5 VDC (17 mA maximum current draw)

Housing

Material

Aluminum A356T6 (<0.20% copper), optional 316 stainless steel

Cable Entry

3

4

" NPT and M20

5.3.2 Performance

Accuracy

±0.015"

Repeatability

±0.005% of full span or 0.005" (0.127 mm) (whichever is greater)

Linearity

0.020% of full span or 0.031" (0.794 mm) (whichever is greater)

Maximum level rate of change

6 inches per second

Response time

0.1 second

Warm-up

<5 second

Upper dead zone

None

Lower dead zone

<2" (5 cm), SIL 2: <5" (13 cm)

Ambient temperature range

Transmitter:

-40° to +175° F (-40° to +80° C)

LCD:

-10° to +160° F (-20° to +70° C)

Process temperature

External Mount:

-40° to +248° F (-40° to +120° C)

-320° to +850° F (-195° to +455° C) (with factory insulated MLI)

Direct Insertion:

-40° to +200° F (-40° to +95° C)

High temperature probe:

-40° to +500° F (-40° to +260° C)

Humidity

0 to 99% non-condensing

Electromagnetic compliance

EN 61326

Maximum Pressure (Direct Insertion)

1700 psig @ +100° F

Advertising