94

AUXILIARY

MODE

AUXILIARY

INPUT CAN BE

USED FOR

TIMER, DOOR

RELEASE

SWITCH, ETC.

95

ALARM MODE

THE SYSTEM

WILL BEEP OR

CALL THE

REMOTE PHONE

IF INVALID

ACCESS CODES

ARE ENTERED.

Step 1

Entering The Programming

Mode: Press 0 and # simultaneously
then release.
If you are in the pro-
gramming mode, proceed to step 2.

Step 2

Enter the 4-digit Master

Code (factory default is 0000) and you
will hear “One Short Beep”. If you
entered an invalid master code you will
hear “One Long Beep”, repeat
step 1. Should your master code
become lost or forgotten Reset Master
Code.

Step 3

Enter 94 then #, you will

hear “One Short Beep”.

Step 4

Enter

0 = AUXIN is disabled or
1 = is enabled and door will open

according to Door Open Interval
programmed on function Code
“92”) or

2 = AUXIN is enabled and opening

door is controlled by the AUXIN)

then press #, you will hear “One Short
Beep”.

Step 5

Enter another Function Code

to program another parameter other-
wise press

∗ to exit and you will hear

“Three Short Beeps”.

Step 1

Entering The Programming

Mode: Press 0 and # simultaneously
then release.
If you are in the pro-
gramming mode, proceed to step 2.

Step 2

Enter the 4-digit Master

Code (factory default is 0000) and you
will hear “One Short Beep”. If you
entered an invalid master code you will
hear “One Long Beep”, repeat
step 1. Should your master code
become lost or forgotten see Reset
Master Code.

Step 3

Enter 95 then #, you will

hear “One Short Beep”.

Step 4

Enter

0 for local (system’s speaker will beep

and the system will be blocked-out
for 60 seconds)

1 system will make an emergency call

to a premise or remote location and
the system will be blocked-out for 60
seconds then press #, you will hear

Step 1

Pick up the phone and wait

for a dial tone.

Step 2

Press # # and you will hear

“One Short Beep”.

Step 3

Press # and you will hear

“One Short Beep”.

Step 4

Enter the Function Code 94

then press #, you will hear “One Short
Beep”.

Step 5

Enter

0 = AUI is disabled or
1 = AUI is enabled, door open time is

control by door open interval
programmed on function code 92,
or

2 = AUI is enabled, door open time is
controlled by the AUI)
then press #, you will hear “One Short
Beep”.

Step 6

Enter another function code

to program a different parameter or
exit the program by pressing

∗ ∗ and

you will hear “Three Short Beeps”.

Step 1

Pick up the phone and wait

for a dial tone.

Step 2

Press # # and you will hear

“One Short Beep”.

Step 3

Press # and you will hear

“One Short Beep”.

Step 4

Enter the Function Code 95

then press #, you will hear “One Short
Beep”.

Step 5

Enter

0 = the system will beep via its

speaker or

1 = the system will call into a premise

or remote location) then press #,
you will hear “One Short Beep”.

Step 6

Enter another function code

to program a different parameter or
exit the program by pressing

∗ ∗ and

you will hear “Three Short Beeps”.

Step 5

Enter another function code

to program a different parameter or
exit the program by pressing

∗ ∗ and

you will hear “Three Short Beeps”.

Step 1

Call to the AeGIS 4000BP

system (you must know the system’s
phone number), you will hear: “One
Short Beep”,
the gate is locked. “Two
Short Beeps”,
the gate is unlocked.

Step 2

Press # then enter a valid

master code and you will hear:
“One Short Beep”, the master code

is accepted then press # and you will
hear “One Short Beep”.

“One Long Beep”, the master code

is rejected and the connection will be
disconnected.

Step 3

Enter the Function Code 94

then press #, you will hear “One Short
Beep”.

Step 4

Enter

0 = AUI is disabled or
1 = AUI is enabled, door open time is

control by door open interval
programmed on function code 92,
or

2 = AUI is enabled, door open time is
controlled by the AUI)
then press #, you will hear “One Short
Beep”.

Step 5

Enter another function code

to program a different parameter or
exit the program by pressing

∗ ∗ and

you will hear “Three
Short Beeps”.

Step 1

Call to the AeGIS 4000BP

system (you must know the system’s
phone number), you will hear: “One
Short Beep”,
the gate is locked. “Two
Short Beeps”,
the gate is unlocked.

Step 2

Press # then enter a valid

master code and you will hear:
“One Short Beep”, the master code

is accepted then press # and you will
hear “One Short Beep”.

“One Long Beep”, the master code

is rejected and the connection will be
disconnected.

Step 3

Enter the Function Code 95

then press #, you will hear “One Short
Beep”.

Step 4

Enter

0 = the system will beep via its

speaker or

1 = the system will call into a premise

or remote location then press #,
you will hear “One Short Beep”.

Function

Local Programming

Premise Phone

Remote Phone

Pach and Company