ADC Soneplex P-61-743 User Manual

Page 23

Advertising
background image

ADCP-61-743

• Issue 3 • September 2004

Page 23

© 2004, ADC Telecommunications, Inc.

Table 3. RTAU Configuration Fields, continued

FIELD

TYPE

OPTIONS

DESCRIPTION

DEFAULT

Elapsed Time ES

Display

only

None

Six-digit counter or blank.

Blank

Elapsed Time EFS

Display

only

None

Six-digit counter or blank.

Blank

Test Timeout in Minutes

Input

0 to 1440

Timeout counter for test access. If the counter

is set to a number higher than “0” and then

reaches “0” during test, the Mode field will be

set to DISABLE automatically. If the counter is

set to “0”, the test timeout will be turned off,

and the test will have unlimited time.

60

Measurement Toggle

and

Display

OVERVIEW: Start a measurement by selecting

START at the Measurement field. The RTAU will

wait for pattern sync and frame sync for framed

patterns before starting the measurement. After

synchronizing, the measurement display will

change to RUNNING. Stop any measurement by

selecting STOP. Refer to Figure 17 for a RTAU

configuration screen showing a test that is starting.

Note: If the Mode is set to MONE, MONF,

LOOPE, or LOOPF, only frame sync is required

before starting the measurement. If the pattern is

not in sync, then the Data Error Counts will read

“N/A” until pattern sync is established.

STOP

START

Initiate

measurement.

STOP

Terminate

measurement.

Note: Setting the

Mode field to DISABLE also stops any

measurement in progress as if the Measurement

field had been set to STOP.

RUNNING (display)

Measurement active.

Waiting on Sync

Display

only

None

This parameter is displayed to the right of the

Measurement field when the Measurement field

is set to START. The WAITING ON SYNC

message is display-only; it only shows up when

the RTAU is waiting for either frame or pattern

sync. Examine the status section to determine

what sync is needed.

Blank

Mode

Toggle

DISABLE

To end the test session, restore the tested circuit to

normal operation by selecting DISABLE.

DISABLE

Advertising