ADC Soneplex P-61-743 User Manual

Page 29

Advertising
background image

ADCP-61-743

• Issue 3 • September 2004

Page 29

© 2004, ADC Telecommunications, Inc.

Table 4. TL1 Commands Used for the RTAU

COMMAND

DESCRIPTION

CHG-ACCMD-T1

Change Access Mode T1

CHG-LPBK-T1

Change Loopback T1

CHG-TSTSIG-T1

Change Test Signal T1

CONN-TACC-T1

Connect Test Access T1

DISC-MEAS Disconnect

Measurement

DISC-TACC

Disconnect Test Access Metallic/Digital

DISC-TSTSIG Disconnect Test Signal

MEAS-SIG-T1

Measure Signal T1

REPT-RSLT Report

Result

TST-INSERRBITS

Test Insert Error Bits

7 SPECIFICATIONS

The technical specifications for the RTAU modules are given in Table 5.

Table 5. RTAU Specifications

PARAMETER

SPECIFICATION

REMARKS

Input Power

Input Current (Max.)

175 mA at

48 Volts

Input Current (Nominal)

100 mA at

48 Volts

Input Voltage (Nominal)

–48 Vdc

Input Voltage Range

–42 to –60 Vdc

Power Consumption /
Dissipation (Max.)

8.2 watts

DS1 Jack Access

Electrical Interface

Bipolar

Termination

100 ohms nominal

± 5%

Jack Type

Bantam

Line Code

AMI or B8ZS

Controlled by front panel switch

Line Rate

1.544 Mbps ± 130 ppm max.

Dimensions

Height

× Width × Depth

9.5

Ч 9.9 Ч 1.0 inches

(24.1

Ч 25.1 Ч 2.5 cm)

Weight

12 oz. (.34 kg)

Environment

Operating Temperature

–40

° to 149° F (–40° to 65° C)

Storage Temperature

–40

° to 158° F (–40° to 70° C)

Relative Humidity (Operating)

5% to 95%

No condensation

Altitude (Operating
or Non-operating)

–1,312 to + 14,764 ft.
(–

400 to +4,500 m)